Emergency Lighting - Emergency Lighting in the Cabin does not come on when the LIGHT EMER Pushbutton Switch and its integral Light are on
TASK 33-51-00-810-811-A
Emergency Lighting - Emergency Lighting in the Cabin does not come on when the LIGHT EMER Pushbutton Switch and its integral Light are on
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 33-51-00-710-070-A
Subtask 33-51-00-810-060-A ** ON A/C NOT FOR ALL
Subtask 33-51-00-860-072-A
[Rev.8 from Aug 2018]
2026.04.04 04:32:08 UTC
Emergency Lighting - Emergency Lighting in the Cabin does not come on when the LIGHT EMER Pushbutton Switch and its integral Light are on
1. Possible Causes
- FAP [120RH]
- wiring
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 23-73-00-740-005 | BITE-Test of the Cabin Intercommunication Data System (CIDS) through the CFDS |
| AMM 23-73-12-000-002 | Removal of the Forward Attendant Panel |
| AMM 23-73-12-000-007 | Removal of the Flight Attendant Panel |
| AMM 23-73-12-400-002 | Installation of the Forward Attendant Panel |
| AMM 23-73-12-400-007 | Installation of the Flight Attendant Panel |
| AMM 33-51-00-710-007 | Operational Test of the Emergency Lighting in the Cabin with the 'LIGHT EMER' Pushbutton Switch |
| ASM 335101 | |
| ASM 335102 |
Subtask 33-51-00-710-070-A
A. Do the operational test of the emergency lighting in the cabin by LIGHT EMER pushbutton switch AMM 33-51-00-710-007.
4. Fault IsolationSubtask 33-51-00-810-060-A ** ON A/C NOT FOR ALL
A. If the emergency lighting in the cabin does not come on:
Subtask 33-51-00-810-060-C ** ON A/C NOT FOR ALL - do the BITE-test of the Cabin Intercommunication Data-System (CIDS) AMM 23-73-00-740-005 and monitor the functions of the Forward Attendant Panel (FAP) (120RH),
- make sure that the FAP [120RH] operates correctly and replace it if necessary AMM 23-73-12-000-002 and AMM 23-73-12-400-002.
- do a check and repair as necessary the wiring between:
FAP (120RH) connector A/15 and EPSU (10WL) connector A/A or EPSU (11WL) connector A/A or EPSU (12WL) connector A/A or EPSU (13WL) connector A/A
ASM 335101 and ASM 335102.
A. If the emergency lighting in the cabin does not come on:
Subtask 33-51-00-710-071-A - do the interface and power-up test of the Cabin Intercommunication Data-System (CIDS) AMM 23-73-00-740-005 and monitor the functions of the Flight Attendant Panel (FAP) (120RH),
- make sure that the FAP [120RH] operates correctly and replace it if necessary AMM 23-73-12-000-007 and AMM 23-73-12-400-007.
- do a check and repair as necessary the wiring between:
FAP (120RH) connector A/15 and EPSU (10WL) connector A/A or EPSU (11WL) connector A/A or EPSU (12WL) connector A/A or EPSU (13WL) connector A/A
ASM 335101 and ASM 335102.
B. Do the test given in Para. 3.
5. Close-upSubtask 33-51-00-860-072-A
A. Put the aircraft back to its initial configuration.