W DOC AIRBUS | TSM A320F

Emergency Lighting - Emergency Lighting in the Cabin does not come on when the EMER EXIT LT Switch is in the ON Position


TASK 33-51-00-810-810-A
Emergency Lighting - Emergency Lighting in the Cabin does not come on when the EMER EXIT LT Switch is in the ON Position


1. Possible Causes
  • SW-SIGNS/EMER EXIT LT [4WL]
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 33-51-00-710-008
Operational Test of the Emergency Lighting in the Cabin with the 'EMER EXIT LT' Switch
ASM 335101
3. Fault Confirmation
Subtask 33-51-00-710-068-A
A. Do the operational test of the emergency lighting in the cabin by EMER EXIT LT switch AMM 33-51-00-710-008.
4. Fault Isolation
Subtask 33-51-00-810-059-A
A. If the emergency lighting in the cabin does not come on:
  • do a check of the SW-SIGNS/EMER EXIT LT [4WL] and replace it if necessary.
   (1) If the fault continues:
  • do a check and repair the wiring between:
    SW-SIGNS/EMER EXIT LT [4WL] switch pin 3A and POWER SUPPLY UNIT-EMERGENCY (10WL) connector A/A,
    SW-SIGNS/EMER EXIT LT [4WL] switch pin 3B and GND,
    SW-SIGNS/EMER EXIT LT [4WL] switch pin 1C and GND ASM 335101.
Subtask 33-51-00-710-069-A
B. Do the test given in Para. 3.
5. Close-up
Subtask 33-51-00-860-055-A
A. Put the aircraft back to its initial configuration.
[Rev.8 from Aug 2018] 2026.04.04 04:32:08 UTC