W DOC AIRBUS | TSM A320F

EPSU - 28 VDC Fault Message


TASK 33-51-00-810-805-A
EPSU - 28 VDC Fault Message


1. Possible Causes
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 33-51-00-710-001
Operational Test of the Emergency Lights
ASM 335101
ASM 335102
AMM 33-51-38-000-001
Removal of the Emergency Power-Supply Unit (EPSU)
AMM 33-51-38-400-001
Installation of the Emergency Power-Supply Unit (EPSU)
3. Fault Confirmation
CAUTION: DO NOT USE THE TEACH-IN PROCEDURE AS AN ALTERNATIVE FOR TROUBLESHOOTING. A TEACH-IN PROCEDURE IS NOT A RESET PROCEDURE. BEFORE YOU DO A TEACH-IN PROCEDURE, MAKE SURE THAT YOU CORRECTED ALL FAILURES. IF YOU DO NOT OBEY THIS, FAILURES CAN CAUSE A MALFUNCTION OF THE CABIN EMERGENCY LIGHTING SYSTEM.
Subtask 33-51-00-710-058-A ** ON A/C NOT FOR ALL
A. Test
   (1) Do the operational test of the emergency lighting system AMM 33-51-00-710-001.
4. Fault Isolation
Subtask 33-51-00-810-054-A ** ON A/C NOT FOR ALL
A. If the operational test gives the maintenance message:
   (1) EPSU 28 VDC FWD L:
  • do a check for 28 VDC at the POWER SUPPLY UNIT-EMERGENCY (10WL).
     (a) If there is 28 VDC:
     (b) If there is no 28 VDC:
  • do a check and repair the wiring between:
    POWER SUPPLY UNIT-EMERGENCY (10WL) pin V and CB 2WL,
    POWER SUPPLY UNIT-EMERGENCY (10WL) pin U and GND ASM 335101 and ASM 335102.
   (2) EPSU 28 VDC EMER L:
  • do a check for 28 VDC at the POWER SUPPLY UNIT-EMERGENCY (11WL).
     (a) If there is 28 VDC:
     (b) If there is no 28 VDC:
  • do a check and repair the wiring between:
    POWER SUPPLY UNIT-EMERGENCY (11WL) pin V and CB 1WL,
    POWER SUPPLY UNIT-EMERGENCY (11WL) pin U and GND ASM 335101 and ASM 335102.
   (3) EPSU 28 VDC EMER R:
  • do a check for 28 VDC at POWER SUPPLY UNIT-EMERGENCY (12WL).
     (a) If there is 28 VDC:
     (b) If there is no 28 VDC:
  • do a check and repair the wiring between:
    POWER SUPPLY UNIT-EMERGENCY (12WL) pin V and CB 2WL,
    POWER SUPPLY UNIT-EMERGENCY (12WL) pin U and GND ASM 335101 and ASM 335102.
   (4) EPSU 28 VDC AFT L:
  • do a check for 28 VDC at POWER SUPPLY UNIT-EMERGENCY (13WL).
     (a) If there is 28 VDC:
     (b) If there is no 28 VDC:
  • do a check and repair the wiring between:
    POWER SUPPLY UNIT-EMERGENCY (13WL) pin V and CB 1WL,
    POWER SUPPLY UNIT-EMERGENCY (13WL) pin U and GND ASM 335101 and ASM 335102.
Subtask 33-51-00-710-059-A ** ON A/C NOT FOR ALL
B. Do the test as given in the Para. 3.A.
5. Close-up
Subtask 33-51-00-860-068-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.