EPSU - Battery Capacity Fault
TASK 33-51-00-810-803-A
EPSU - Battery Capacity Fault
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 33-51-00-810-052-A ** ON A/C NOT FOR ALL
Subtask 33-51-00-860-066-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:32:07 UTC
EPSU - Battery Capacity Fault
1. Possible Causes
- BATTERY
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 33-51-00-710-003 | Check of the Battery Capacity |
| AMM 33-51-38-000-002 | Removal of the Battery of the Emergency Power-Supply Unit |
| AMM 33-51-38-400-002 | Installation of the Battery of the Emergency Power-Supply Unit |
CAUTION:
DO NOT USE THE TEACH-IN PROCEDURE AS AN ALTERNATIVE FOR TROUBLESHOOTING. A TEACH-IN PROCEDURE IS NOT A RESET PROCEDURE. BEFORE YOU DO A TEACH-IN PROCEDURE, MAKE SURE THAT YOU CORRECTED ALL FAILURES. IF YOU DO NOT OBEY THIS, FAILURES CAN CAUSE A MALFUNCTION OF THE CABIN EMERGENCY LIGHTING SYSTEM.
Subtask 33-51-00-710-054-A ** ON A/C NOT FOR ALL A. Do the operational test 'Check Battery Capacity by TEST EMER LIGHT BAT Membrane Switch' AMM 33-51-00-710-003.
4. Fault IsolationSubtask 33-51-00-810-052-A ** ON A/C NOT FOR ALL
A. If after the operational test the green LED 'BAT OK' does not come on:
Subtask 33-51-00-710-055-A ** ON A/C NOT FOR ALL - replace the related BATTERY AMM 33-51-38-000-002 and AMM 33-51-38-400-002.
NOTE: Make sure that you install a fully charged battery.
B. Do the operational test as given in the Para. 3.A.
5. Close-upSubtask 33-51-00-860-066-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.