W DOC AIRBUS | TSM A320F

EPSU - Battery Capacity Fault


TASK 33-51-00-810-803-A
EPSU - Battery Capacity Fault


1. Possible Causes
  • BATTERY
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 33-51-00-710-003
Check of the Battery Capacity
AMM 33-51-38-000-002
Removal of the Battery of the Emergency Power-Supply Unit
AMM 33-51-38-400-002
Installation of the Battery of the Emergency Power-Supply Unit
3. Fault Confirmation
CAUTION: DO NOT USE THE TEACH-IN PROCEDURE AS AN ALTERNATIVE FOR TROUBLESHOOTING. A TEACH-IN PROCEDURE IS NOT A RESET PROCEDURE. BEFORE YOU DO A TEACH-IN PROCEDURE, MAKE SURE THAT YOU CORRECTED ALL FAILURES. IF YOU DO NOT OBEY THIS, FAILURES CAN CAUSE A MALFUNCTION OF THE CABIN EMERGENCY LIGHTING SYSTEM.
Subtask 33-51-00-710-054-A ** ON A/C NOT FOR ALL
A. Do the operational test 'Check Battery Capacity by TEST EMER LIGHT BAT Membrane Switch' AMM 33-51-00-710-003.
4. Fault Isolation
Subtask 33-51-00-810-052-A ** ON A/C NOT FOR ALL
A. If after the operational test the green LED 'BAT OK' does not come on:
NOTE: Make sure that you install a fully charged battery.
Subtask 33-51-00-710-055-A ** ON A/C NOT FOR ALL
B. Do the operational test as given in the Para. 3.A.
5. Close-up
Subtask 33-51-00-860-066-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.