EPSU - Battery Fault
TASK 33-51-00-810-802-A
EPSU - Battery Fault
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 33-51-00-810-051-C ** ON A/C NOT FOR ALL
Subtask 33-51-00-860-065-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:32:06 UTC
EPSU - Battery Fault
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 33-51-00-710-001 | Operational Test of the Emergency Lights |
| AMM 33-51-00-710-006 | Operational Test of Emergency Lights not with CIDS |
| AMM 33-51-38-000-001 | Removal of the Emergency Power-Supply Unit (EPSU) |
| AMM 33-51-38-000-002 | Removal of the Battery of the Emergency Power-Supply Unit |
| AMM 33-51-38-400-001 | Installation of the Emergency Power-Supply Unit (EPSU) |
| AMM 33-51-38-400-002 | Installation of the Battery of the Emergency Power-Supply Unit |
CAUTION:
DO NOT USE THE TEACH-IN PROCEDURE AS AN ALTERNATIVE FOR TROUBLESHOOTING. A TEACH-IN PROCEDURE IS NOT A RESET PROCEDURE. BEFORE YOU DO A TEACH-IN PROCEDURE, MAKE SURE THAT YOU CORRECTED ALL FAILURES. IF YOU DO NOT OBEY THIS, FAILURES CAN CAUSE A MALFUNCTION OF THE CABIN EMERGENCY LIGHTING SYSTEM.
Subtask 33-51-00-710-052-A ** ON A/C NOT FOR ALL 4. Fault IsolationSubtask 33-51-00-810-051-C ** ON A/C NOT FOR ALL
A. If the operational test gives the maintenance message:
(1) EPSU BATTERY FWD L:
Subtask 33-51-00-710-053-A ** ON A/C NOT FOR ALL (1) EPSU BATTERY FWD L:
- do the operational test of the battery of the POWER SUPPLY UNIT-EMERGENCY (10WL) AMM 33-51-00-710-006.
- Replace the BATTERY AMM 33-51-38-000-002 and AMM 33-51-38-400-002,
- do the operational test of the battery again.
- replace the POWER-EMERGENCY SUPPLY [10WL] AMM 33-51-38-000-001 and AMM 33-51-38-400-001.
- do the operational test of the battery of the POWER SUPPLY UNIT-EMERGENCY (11WL) AMM 33-51-00-710-006.
- Replace the BATTERY AMM 33-51-38-000-002 and AMM 33-51-38-400-002,
- do the operational test of the battery again.
- replace the EPSU [11WL] AMM 33-51-38-000-001 and AMM 33-51-38-400-001.
- do the operational test of the battery of the POWER SUPPLY UNIT-EMERGENCY (12WL) AMM 33-51-00-710-006.
- Replace the BATTERY AMM 33-51-38-000-002 and AMM 33-51-38-400-002,
- do the operational test of the battery again.
- replace the EPSU [12WL] AMM 33-51-38-000-001 and AMM 33-51-38-400-001.
- do the operational test of the battery of the POWER SUPPLY UNIT-EMERGENCY (13WL) AMM 33-51-00-710-006.
- Replace the BATTERY AMM 33-51-38-000-002 and AMM 33-51-38-400-002,
- do the operational test of the battery again.
- replace the EPSU [13WL] AMM 33-51-38-000-001 and AMM 33-51-38-400-001.
B. Do the test as given in the Para. 3.A.
5. Close-upSubtask 33-51-00-860-065-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.