EPSU - Emergency Power-Supply Unit Fault
TASK 33-51-00-810-801-A
EPSU - Emergency Power-Supply Unit Fault
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 33-51-00-810-067-A ** ON A/C NOT FOR ALL
Subtask 33-51-00-860-064-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:32:06 UTC
EPSU - Emergency Power-Supply Unit Fault
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 33-51-00-710-001 | Operational Test of the Emergency Lights |
| ASM 335101 | |
| ASM 335102 | |
| ASM 335104 | |
| AMM 33-51-38-000-001 | Removal of the Emergency Power-Supply Unit (EPSU) |
| AMM 33-51-38-400-001 | Installation of the Emergency Power-Supply Unit (EPSU) |
CAUTION:
DO NOT USE THE TEACH-IN PROCEDURE AS AN ALTERNATIVE FOR TROUBLESHOOTING. A TEACH-IN PROCEDURE IS NOT A RESET PROCEDURE. BEFORE YOU DO A TEACH-IN PROCEDURE, MAKE SURE THAT YOU CORRECTED ALL FAILURES. IF YOU DO NOT OBEY THIS, FAILURES CAN CAUSE A MALFUNCTION OF THE CABIN EMERGENCY LIGHTING SYSTEM.
Subtask 33-51-00-710-050-A ** ON A/C NOT FOR ALL 4. Fault IsolationSubtask 33-51-00-810-067-A ** ON A/C NOT FOR ALL
A. If the test gives a different maintenance message, do the trouble shooting procedure related to the maintenance message.
Subtask 33-51-00-810-050-A ** ON A/C NOT FOR ALL B. If the operational test gives the maintenance message:
(1) EPSU UNIT FWD L:
Subtask 33-51-00-710-051-A ** ON A/C NOT FOR ALL (1) EPSU UNIT FWD L:
- replace the POWER-EMERGENCY SUPPLY [10WL] AMM 33-51-38-000-001 and AMM 33-51-38-400-001.
- check all connected signs and lights for a short-circuit and replace if necessary ASM 335101 and ASM 335104,
- if you find one or more defective signs and lights, replace the POWER-EMERGENCY SUPPLY [10WL] AMM 33-51-38-000-001 and AMM 33-51-38-400-001.
- do a check for a short to ground and repair the wiring if necessary ASM 335101 and ASM 335104:
from EPSU (10WL) pin E to the connector(s) of the related signs and lights,
from EPSU (10WL) pin F to the connector(s) of the related signs and lights,
from EPSU (10WL) pin G to the connector(s) of the related signs and lights,
from EPSU (10WL) pin N to the connector(s) of the related signs and lights,
from EPSU (10WL) pin R to the connector(s) of the related signs and lights,
from EPSU (10WL) pin T to the connector(s) of the related signs and lights,
from EPSU (10WL) pin -B to the connector(s) of the related signs and lights,
from EPSU (10WL) pin -J to the connector(s) of the related signs and lights, - if you find a short to ground in the wiring, replace the POWER-EMERGENCY SUPPLY [10WL] AMM 33-51-38-000-001 and AMM 33-51-38-400-001.
- do a check and repair the wiring if necessary ASM 335101:
from EPSU (10WL) pin -P to DEU-B (300RH1) pin B/17,
from EPSU (10WL) pin X to DEU-B (300RH1) pin B/16,
from EPSU (10WL) pin L to GND,
from EPSU (10WL) pin M to GND,
from EPSU (10WL) pin U to GND,
from EPSU (10WL) pin -R to GND,
from EPSU (10WL) pin -M to GND.
- replace the EPSU [11WL] AMM 33-51-38-000-001 and AMM 33-51-38-400-001.
- check all connected signs and lights for a short-circuit and replace if necessary ASM 335102 and ASM 335104,
- if you find one or more defective signs and lights, replace the EPSU [11WL] AMM 33-51-38-000-001 and AMM 33-51-38-400-001.
- do a check for a short to ground and repair the wiring if necessary ASM 335102 and ASM 335104:
from EPSU (11WL) pin E to the connector(s) of the related signs and lights,
from EPSU (11WL) pin F to the connector(s) of the related signs and lights,
from EPSU (11WL) pin G to the connector(s) of the related signs and lights,
from EPSU (11WL) pin N to the connector(s) of the related signs and lights,
from EPSU (11WL) pin R to the connector(s) of the related signs and lights,
from EPSU (11WL) pin T to the connector(s) of the related signs and lights,
from EPSU (11WL) pin -B to the connector(s) of the related signs and lights,
from EPSU (11WL) pin -J to the connector(s) of the related signs and lights, - if you find a short to ground in the wiring, replace the EPSU [11WL] AMM 33-51-38-000-001 and AMM 33-51-38-400-001.
- do a check and repair the wiring if necessary ASM 335102:
from EPSU (11WL) pin -P to DEU-B (300RH4) pin B/17,
from EPSU (11WL) pin X to DEU-B (300RH4) pin B/16,
from EPSU (11WL) pin L to GND,
from EPSU (11WL) pin M to GND,
from EPSU (11WL) pin U to GND,
from EPSU (11WL) pin -R to GND,
from EPSU (11WL) pin -M to GND.
- replace the EPSU [12WL] AMM 33-51-38-000-001 and AMM 33-51-38-400-001.
- check all connected signs and lights for a short-circuit and replace if necessary ASM 335102 and ASM 335104,
- if you find one or more defective signs and lights, replace the EPSU [12WL] AMM 33-51-38-000-001 and AMM 33-51-38-400-001.
- do a check for a short to ground and repair the wiring if necessary ASM 335102 and ASM 335104:
from EPSU (12WL) pin E to the connector(s) of the related signs and lights,
from EPSU (12WL) pin F to the connector(s) of the related signs and lights,
from EPSU (12WL) pin G to the connector(s) of the related signs and lights,
from EPSU (12WL) pin N to the connector(s) of the related signs and lights,
from EPSU (12WL) pin R to the connector(s) of the related signs and lights,
from EPSU (12WL) pin T to the connector(s) of the related signs and lights,
from EPSU (12WL) pin -B to the connector(s) of the related signs and lights,
from EPSU (12WL) pin -J to the connector(s) of the related signs and lights, - if you find a short to ground in the wiring, replace the EPSU [12WL] AMM 33-51-38-000-001 and AMM 33-51-38-400-001.
- do a check and repair the wiring if necessary ASM 335102:
from EPSU (12WL) pin -P to DEU-B (300RH4) pin B/20,
from EPSU (12WL) pin X to DEU-B (300RH4) pin B/19,
from EPSU (12WL) pin L to GND,
from EPSU (12WL) pin M to GND,
from EPSU (12WL) pin U to GND,
from EPSU (12WL) pin -R to GND,
from EPSU (12WL) pin -M to GND.
- replace the EPSU [13WL] AMM 33-51-38-000-001 and AMM 33-51-38-400-001.
- check all connected signs and lights for a short-circuit and replace if necessary ASM 335102 and ASM 335104,
- if you find one or more defective signs and lights, replace the EPSU [13WL] AMM 33-51-38-000-001 and AMM 33-51-38-400-001.
- do a check for a short to ground and repair the wiring if necessary ASM 335102 and ASM 335104:
from EPSU (13WL) pin E to the connector(s) of the related signs and lights,
from EPSU (13WL) pin F to the connector(s) of the related signs and lights,
from EPSU (13WL) pin G to the connector(s) of the related signs and lights,
from EPSU (13WL) pin N to the connector(s) of the related signs and lights,
from EPSU (13WL) pin R to the connector(s) of the related signs and lights,
from EPSU (13WL) pin T to the connector(s) of the related signs and lights,
from EPSU (13WL) pin -B to the connector(s) of the related signs and lights,
from EPSU (13WL) pin -J to the connector(s) of the related signs and lights, - if you find a short to ground in the wiring, replace the EPSU [13WL] AMM 33-51-38-000-001 and AMM 33-51-38-400-001.
- do a check and repair the wiring if necessary ASM 335102:
from EPSU (13WL) pin -P to DEU-B (300RH5) pin B/17,
from EPSU (13WL) pin X to DEU-B (300RH5) pin B/16,
from EPSU (13WL) pin L to GND,
from EPSU (13WL) pin M to GND,
from EPSU (13WL) pin U to GND,
from EPSU (13WL) pin -R to GND,
from EPSU (13WL) pin -M to GND.
C. Do the test as given in the Para. 3.A.
5. Close-upSubtask 33-51-00-860-064-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.