W DOC AIRBUS | TSM A320F

EPSU - Emergency Power-Supply Unit Fault


TASK 33-51-00-810-801-A
EPSU - Emergency Power-Supply Unit Fault


1. Possible Causes
  • POWER-EMERGENCY SUPPLY [10WL]
  • signs and lights
  • wiring
  • EPSU [11WL]
  • EPSU [12WL]
  • EPSU [13WL]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 33-51-00-710-001
Operational Test of the Emergency Lights
ASM 335101
ASM 335102
ASM 335104
AMM 33-51-38-000-001
Removal of the Emergency Power-Supply Unit (EPSU)
AMM 33-51-38-400-001
Installation of the Emergency Power-Supply Unit (EPSU)
3. Fault Confirmation
CAUTION: DO NOT USE THE TEACH-IN PROCEDURE AS AN ALTERNATIVE FOR TROUBLESHOOTING. A TEACH-IN PROCEDURE IS NOT A RESET PROCEDURE. BEFORE YOU DO A TEACH-IN PROCEDURE, MAKE SURE THAT YOU CORRECTED ALL FAILURES. IF YOU DO NOT OBEY THIS, FAILURES CAN CAUSE A MALFUNCTION OF THE CABIN EMERGENCY LIGHTING SYSTEM.
Subtask 33-51-00-710-050-A ** ON A/C NOT FOR ALL
A. Do the operational test of the emergency lighting system AMM 33-51-00-710-001.
4. Fault Isolation
Subtask 33-51-00-810-067-A ** ON A/C NOT FOR ALL
A. If the test gives a different maintenance message, do the trouble shooting procedure related to the maintenance message.
Subtask 33-51-00-810-050-A ** ON A/C NOT FOR ALL
B. If the operational test gives the maintenance message:
   (1) EPSU UNIT FWD L:
     (a) If the fault continues:
     (b) If the fault continues:
  • do a check for a short to ground and repair the wiring if necessary ASM 335101 and ASM 335104:
    from EPSU (10WL) pin E to the connector(s) of the related signs and lights,
    from EPSU (10WL) pin F to the connector(s) of the related signs and lights,
    from EPSU (10WL) pin G to the connector(s) of the related signs and lights,
    from EPSU (10WL) pin N to the connector(s) of the related signs and lights,
    from EPSU (10WL) pin R to the connector(s) of the related signs and lights,
    from EPSU (10WL) pin T to the connector(s) of the related signs and lights,
    from EPSU (10WL) pin -B to the connector(s) of the related signs and lights,
    from EPSU (10WL) pin -J to the connector(s) of the related signs and lights,
  • if you find a short to ground in the wiring, replace the POWER-EMERGENCY SUPPLY [10WL] AMM 33-51-38-000-001 and AMM 33-51-38-400-001.
     (c) If the fault continues:
  • do a check and repair the wiring if necessary ASM 335101:
    from EPSU (10WL) pin -P to DEU-B (300RH1) pin B/17,
    from EPSU (10WL) pin X to DEU-B (300RH1) pin B/16,
    from EPSU (10WL) pin L to GND,
    from EPSU (10WL) pin M to GND,
    from EPSU (10WL) pin U to GND,
    from EPSU (10WL) pin -R to GND,
    from EPSU (10WL) pin -M to GND.
   (2) EPSU UNIT EMER L:
     (a) If the fault continues:
     (b) If the fault continues:
  • do a check for a short to ground and repair the wiring if necessary ASM 335102 and ASM 335104:
    from EPSU (11WL) pin E to the connector(s) of the related signs and lights,
    from EPSU (11WL) pin F to the connector(s) of the related signs and lights,
    from EPSU (11WL) pin G to the connector(s) of the related signs and lights,
    from EPSU (11WL) pin N to the connector(s) of the related signs and lights,
    from EPSU (11WL) pin R to the connector(s) of the related signs and lights,
    from EPSU (11WL) pin T to the connector(s) of the related signs and lights,
    from EPSU (11WL) pin -B to the connector(s) of the related signs and lights,
    from EPSU (11WL) pin -J to the connector(s) of the related signs and lights,
  • if you find a short to ground in the wiring, replace the EPSU [11WL] AMM 33-51-38-000-001 and AMM 33-51-38-400-001.
     (c) If the fault continues:
  • do a check and repair the wiring if necessary ASM 335102:
    from EPSU (11WL) pin -P to DEU-B (300RH4) pin B/17,
    from EPSU (11WL) pin X to DEU-B (300RH4) pin B/16,
    from EPSU (11WL) pin L to GND,
    from EPSU (11WL) pin M to GND,
    from EPSU (11WL) pin U to GND,
    from EPSU (11WL) pin -R to GND,
    from EPSU (11WL) pin -M to GND.
   (3) EPSU UNIT EMER R:
     (a) If the fault continues:
     (b) If the fault continues:
  • do a check for a short to ground and repair the wiring if necessary ASM 335102 and ASM 335104:
    from EPSU (12WL) pin E to the connector(s) of the related signs and lights,
    from EPSU (12WL) pin F to the connector(s) of the related signs and lights,
    from EPSU (12WL) pin G to the connector(s) of the related signs and lights,
    from EPSU (12WL) pin N to the connector(s) of the related signs and lights,
    from EPSU (12WL) pin R to the connector(s) of the related signs and lights,
    from EPSU (12WL) pin T to the connector(s) of the related signs and lights,
    from EPSU (12WL) pin -B to the connector(s) of the related signs and lights,
    from EPSU (12WL) pin -J to the connector(s) of the related signs and lights,
  • if you find a short to ground in the wiring, replace the EPSU [12WL] AMM 33-51-38-000-001 and AMM 33-51-38-400-001.
     (c) If the fault continues:
  • do a check and repair the wiring if necessary ASM 335102:
    from EPSU (12WL) pin -P to DEU-B (300RH4) pin B/20,
    from EPSU (12WL) pin X to DEU-B (300RH4) pin B/19,
    from EPSU (12WL) pin L to GND,
    from EPSU (12WL) pin M to GND,
    from EPSU (12WL) pin U to GND,
    from EPSU (12WL) pin -R to GND,
    from EPSU (12WL) pin -M to GND.
   (4) EPSU UNIT AFT L:
     (a) If the fault continues:
     (b) If the fault continues:
  • do a check for a short to ground and repair the wiring if necessary ASM 335102 and ASM 335104:
    from EPSU (13WL) pin E to the connector(s) of the related signs and lights,
    from EPSU (13WL) pin F to the connector(s) of the related signs and lights,
    from EPSU (13WL) pin G to the connector(s) of the related signs and lights,
    from EPSU (13WL) pin N to the connector(s) of the related signs and lights,
    from EPSU (13WL) pin R to the connector(s) of the related signs and lights,
    from EPSU (13WL) pin T to the connector(s) of the related signs and lights,
    from EPSU (13WL) pin -B to the connector(s) of the related signs and lights,
    from EPSU (13WL) pin -J to the connector(s) of the related signs and lights,
  • if you find a short to ground in the wiring, replace the EPSU [13WL] AMM 33-51-38-000-001 and AMM 33-51-38-400-001.
     (c) If the fault continues:
  • do a check and repair the wiring if necessary ASM 335102:
    from EPSU (13WL) pin -P to DEU-B (300RH5) pin B/17,
    from EPSU (13WL) pin X to DEU-B (300RH5) pin B/16,
    from EPSU (13WL) pin L to GND,
    from EPSU (13WL) pin M to GND,
    from EPSU (13WL) pin U to GND,
    from EPSU (13WL) pin -R to GND,
    from EPSU (13WL) pin -M to GND.
Subtask 33-51-00-710-051-A ** ON A/C NOT FOR ALL
C. Do the test as given in the Para. 3.A.
5. Close-up
Subtask 33-51-00-860-064-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.
[Rev.8 from Aug 2018] 2026.04.04 04:32:06 UTC