Failure of the Forward Avionics-Compartment Dome-Light
TASK 33-35-00-810-805-A
Failure of the Forward Avionics-Compartment Dome-Light
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 33-35-00-720-058-A 4. Fault Isolation
Subtask 33-35-00-810-054-A
[Rev.8 from Aug 2018]
2026.04.04 04:31:57 UTC
Failure of the Forward Avionics-Compartment Dome-Light
1. Possible Causes
RELAY-PWR SPLY, AVIONICS COMPT FWD R LT CTL (25LS) - wiring
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 33-35-00-720-001 | Functional Test of the Avionics-Compartment Lighting |
| ASM 333501 | |
| AIPC 333508 |
Subtask 33-35-00-720-058-A 4. Fault Isolation
Subtask 33-35-00-810-054-A
A. If during the functional test when you push the AVIONICS COMPT LT pushbutton-switch, the forward dome light in the avionics compartment does not operate correctly:
Subtask 33-35-00-720-059-A - remove the
RELAY-PWR SPLY, AVIONICS COMPT FWD R LT CTL (25LS) AIPC 333508.
- do a check for a voltage at pin A/B2 of the power supply relay (25LS).
- do a check and repair the wiring from the power supply relay (25LS) pin A/B3 to the first terminal block ASM 333501.
- do a check and repair the wiring from the power supply relay (25LS) pin A/B2 to the first terminal block ASM 333501.
B. Do the test given in Para. 3.