Socket - No 28 VDC at the Maintenance Socket of the Air Conditioning Compt.
TASK 33-32-00-810-801-A
Socket - No 28 VDC at the Maintenance Socket of the Air Conditioning Compt.
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 33-32-00-710-050-A 4. Fault Isolation
Subtask 33-32-00-810-050-A
Subtask 33-32-00-860-050-A
[Rev.8 from Aug 2018]
2026.04.04 04:31:56 UTC
Socket - No 28 VDC at the Maintenance Socket of the Air Conditioning Compt.
1. Possible Causes
MAINTENANCE SOCKET (2LK) - wiring
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 33-32-00-720-001 | Functional Test of the Maintenance Socket in the Air Conditioning Duct and Accessory Compartment (LK) |
| ASM 333201 |
Subtask 33-32-00-710-050-A 4. Fault Isolation
Subtask 33-32-00-810-050-A
A. If the functional test shows there is no 28 VDC at the maintenance socket:
Subtask 33-32-00-710-051-A - replace the
MAINTENANCE SOCKET (2LK) .
- do a check and repair the wiring between:
CB 1LK and SOCKET 2LK pin +
GND and SOCKET 2LK pin N ASM 333201.
B. Do the test as given in Para. 3. A.
5. Close-upSubtask 33-32-00-860-050-A
A. Put the aircraft back to its initial configuration.