Lavatory Signs - The Toilet Occupied Symbol in the Cockpit does not come on
TASK 33-26-00-810-803-A
Lavatory Signs - The Toilet Occupied Symbol in the Cockpit does not come on
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 33-26-00-710-054-A 4. Fault Isolation
Subtask 33-26-00-810-059-A
Subtask 33-26-00-860-052-A
[Rev.8 from Aug 2018]
2026.04.04 04:31:56 UTC
Lavatory Signs - The Toilet Occupied Symbol in the Cockpit does not come on
1. Possible Causes
- ANN-TOILET/OCCPD [6WJ]
- LAMP
- BOARD-ANN LT TEST & INTFC [18LP]
- WIRING
- C/B-LAV FWD-OCCUPIED or C/B-LAV FWD & MID-OCCUPIED [1WJ]
- MICRO SWITCH LAVATORY [2WJ]
RELAY-OCCUPIED (18LP),
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 33-26-00-710-001 | Operational Test of the Lavatory Lighted Signs WJ |
| ASM 332601 |
Subtask 33-26-00-710-054-A 4. Fault Isolation
Subtask 33-26-00-810-059-A
A. If the test shows that the ANN-TOILET/OCCPD [6WJ] does not come on:
Subtask 33-26-00-710-055-A NOTE: Be sure that the FWD lavtory door is closed and engaged.
(1) If there is 28 VDC: - do a check for 28 VDC at the lamps ASM 332601.
- replace the LAMP
- replace the BOARD-ANN LT TEST & INTFC [18LP]
- do a check and repair the WIRING between:
C/B-LAV FWD-OCCUPIED or C/B-LAV FWD & MID-OCCUPIED [1WJ] and MICRO SWITCH LAVATORY [2WJ] pin C,
MICRO SWITCH LAVATORY [2WJ] pin NO and BOARD-ANN LT TEST & INTFC [18LP] pin 21RELAY-OCCUPIED (18LP), pin 45 and ground,RELAY-OCCUPIED (18LP), pin 10 and ANN-TOILET/OCCPD [6WJ] pin 7,
ASM 332601
B. Do the test as given in the Para. 3. A.
5. Close-upSubtask 33-26-00-860-052-A
A. Put the aircraft back to its initial configuration.