Lavatory Signs - One Lamp in the Lavatory Occupied Sign does not come on
TASK 33-26-00-810-801-A
Lavatory Signs - One Lamp in the Lavatory Occupied Sign does not come on
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 33-26-00-710-050-A 4. Fault Isolation
Subtask 33-26-00-810-050-A
Subtask 33-26-00-860-051-A
[Rev.8 from Aug 2018]
2026.04.04 04:31:56 UTC
Lavatory Signs - One Lamp in the Lavatory Occupied Sign does not come on
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 33-26-00-710-001 | Operational Test of the Lavatory Lighted Signs WJ |
| AMM 33-26-23-000-001 | Removal of the Lavatory-Occupied Signs (WJ) |
| AMM 33-26-23-400-001 | Installation of the Lavatory-Occupied Signs (WJ) |
Subtask 33-26-00-710-050-A 4. Fault Isolation
Subtask 33-26-00-810-050-A
A. If the test gives a maintenance message, do the trouble shooting procedure related to the maintenance message.
Subtask 33-26-00-810-056-A B. If the test shows that one LAMP in the FWD SIGN-LAVATORY OCCUPIED [3WJ] does not come on:
Subtask 33-26-00-810-052-A - replace the related LAMP .
- replace the SIGN-LAVATORY OCCUPIED [3WJ] AMM 33-26-23-000-001 and AMM 33-26-23-400-001.
C. If the test shows that one LAMP in the AFT SIGN-LAVATORY OCCUPIED [13WJ] does not come on:
Subtask 33-26-00-710-053-A - replace the related LAMP .
- replace the SIGN-LAVATORY OCCUPIED [13WJ] AMM 33-26-23-000-001 and AMM 33-26-23-400-001.
D. Do the test given in paragraph 3.A.
5. Close-upSubtask 33-26-00-860-051-A
A. Put the aircraft back to its initial configuration.