W DOC AIRBUS | TSM A320F

Lavatory Lighting - In one Lavatory the Lavatory Light cannot be dimmed


TASK 33-24-00-810-803-A
Lavatory Lighting - In one Lavatory the Lavatory Light cannot be dimmed


1. Possible Causes
  • LAV OCCPD SWITCH
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 33-26-00-810-802-A
Lavatory Signs - The Occupied or Unoccupied Symbol in the Lavatory Lighted Sign does not come on
AMM 33-21-11-000-001
Removal of the Ballast Unit, Lampholder and Fluorescent Tube
AMM 33-21-11-400-001
Installation of the Ballast Unit, Lampholder and Fluorescent Tube
AMM 33-24-00-710-001
Operational Test of the Lavatory Lighting LQ
ASM 332401
AMM 33-24-11-000-006
Removal of the Ballast Unit and Lampholder
AMM 33-24-11-000-802
Removal of the Cabin LED Unit (CLEDU)
AMM 33-24-11-400-006
Installation of the Ballast Unit and Lampholder
AMM 33-24-11-400-802
Installation of the Cabin LED Unit (CLEDU)
ASM 332601
AMM 33-26-11-000-001
Removal of the Lavatory Door Microswitch (WJ)
AMM 33-26-11-400-001
Installation of the Lavatory Door Microswitch (WJ)
3. Fault Confirmation
Subtask 33-24-00-710-052-A
A. Do the operational test of the lavatory lighting AMM 33-24-00-710-001.
4. Fault Isolation
Subtask 33-24-00-810-052-A ** ON A/C NOT FOR ALL
A. If the test confirms the fault:
  • adjust the position of the related LAV OCCPD SWITCH in the door frame of the lavatory AMM 33-26-11-400-001.
   (1) If the fault continues:
   (2) If the fault continues:
   (3) If the fault continues:
  • do a check and repair the wiring if necessary between the related:
    BALAST UNIT pin D and the LAV OCCPD SWITCH pin NF ASM 332401 and ASM 332601.
   (4) If the fault continues:
Subtask 33-24-00-810-052-B ** ON A/C NOT FOR ALL
A. If the test confirms the fault:
  • adjust the position of the related LAV OCCPD SWITCH in the door frame of the lavatory AMM 33-26-11-400-001.
   (1) If the fault continues:
   (2) If the fault continues:
   (3) If the fault continues:
   (4) If the fault continues:
  • do a check and repair the wiring if necessary between the related:
    BALAST UNIT (if installed) pin D and the LAV OCCPD SWITCH pin NF ASM 332401 and ASM 332601.
   (5) If the fault continues:
  • do a check and repair the wiring if necessary between the related:
    CLEDU (if installed) pin D and the LAV OCCPD SWITCH pin NF ASM 332401 and ASM 332601.
   (6) If the fault continues:
Subtask 33-24-00-710-055-A
B. Do the test as given in the Para. 3.A .
5. Close-up
Subtask 33-24-00-860-052-A
A. Put the aircraft back to its initial configuration.
[Rev.8 from Aug 2018] 2026.04.04 04:31:55 UTC