Lighting - All Cabin Lights cannot be dimmed or switched off or dim incorrectly
TASK 33-21-00-810-805-A
Lighting - All Cabin Lights cannot be dimmed or switched off or dim incorrectly
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 33-21-00-710-054-A Subtask 33-21-00-710-063-A 4. Fault Isolation
Subtask 33-21-00-810-054-A
Subtask 33-21-00-860-054-A
[Rev.8 from Aug 2018]
2026.04.04 04:31:55 UTC
Lighting - All Cabin Lights cannot be dimmed or switched off or dim incorrectly
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 23-73-00-740-005 | BITE-Test of the Cabin Intercommunication Data System (CIDS) through the CFDS |
| ASM 237309 | |
| AMM 23-73-12-000-002 | Removal of the Forward Attendant Panel |
| AMM 23-73-12-400-002 | Installation of the Forward Attendant Panel |
| AMM 23-73-13-000-001 | Removal of the Aft/Additional Attendant Panel |
| AMM 23-73-13-000-002 | Removal of Additional Attendant Panel |
| AMM 23-73-13-400-001 | Installation of the Aft/Additional Attendant Panel |
| AMM 23-73-13-400-002 | Installation of the Additional Attendant Panel |
| AMM 23-73-34-000-001 | Removal of the CIDS Director |
| AMM 23-73-34-400-001 | Installation of the CIDS Director |
| AWM 237348 | |
| AMM 33-21-00-710-001 | Operational Test of the General Illumination |
Subtask 33-21-00-710-054-A Subtask 33-21-00-710-063-A 4. Fault Isolation
Subtask 33-21-00-810-054-A
A. If the test gives a maintenance message, do the trouble shooting procedure related to the maintenance message.
Subtask 33-21-00-810-059-A B. If there is no CFDS message, but you cannot control all lights correctly:
Subtask 33-21-00-710-064-A - replace the DIR-CIDS, 1 [101RH] AMM 23-73-34-000-001 AMM 23-73-34-400-001.
- replace the FAP [120RH] AMM 23-73-12-000-002 AMM 23-73-12-400-002.
- replace the AAP [126RH] , if installed AMM 23-73-13-000-001 AMM 23-73-13-400-001.
- replace the AAP [128RH] , if installed AMM 23-73-13-000-002 AMM 23-73-13-400-002.
- do a check of the WIRING ASM 237309 and AWM 237348.
C. Do the test as given in the Para. 3.A .
5. Close-upSubtask 33-21-00-860-054-A
A. Put the aircraft back to its initial configuration.