W DOC AIRBUS | TSM A320F

Failure of the Annunciator-Light Test and Interface-Board


TASK 33-14-00-810-806-A
Failure of the Annunciator-Light Test and Interface-Board


1. Possible Causes
  • BOARD-ANN LT TEST & INTFC [8LP]
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ASM 215102
AMM 21-63-00-710-004
Operational Test of the Cockpit and Cabin Temperature Control with CFDS/MCDU
AMM 33-14-33-000-001
Removal of the Annunciator-Light Test and Interface-Board
AMM 33-14-33-400-001
Installation of the Annunciator-Light Test and Interface-Board
3. Fault Confirmation
Subtask 33-14-00-710-056-A ** ON A/C NOT FOR ALL
A. Do the operational test of the cockpit and cabin temperature control with CFDS/MCDU AMM 21-63-00-710-004.
4. Fault Isolation
Subtask 33-14-00-810-059-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message TRIM FAULT RELAY (3LP):
   (1) If the fault continues:
  • do a check and repair the wiring between pin AB/8A of the air-conditioning system controller 2 (57HH) and pin A/45 of the annunciator-light test and interface-board (3LP) ASM 215102.
Subtask 33-14-00-710-057-A ** ON A/C NOT FOR ALL
B. Do the operational test of the cockpit and cabin temperature control with CFDS/MCDU AMM 21-63-00-710-004.
[Rev.8 from Aug 2018] 2026.04.04 04:31:54 UTC