W DOC AIRBUS | TSM A320F

Failure of the Annunciator-Light Test and Interface-Board


TASK 33-14-00-810-805-A
Failure of the Annunciator-Light Test and Interface-Board


1. Possible Causes
  • BOARD-ANN LT TEST & INTFC [20LP]
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ASM 215101
AMM 21-63-00-710-004
Operational Test of the Cockpit and Cabin Temperature Control with CFDS/MCDU
AMM 33-14-33-000-001
Removal of the Annunciator-Light Test and Interface-Board
AMM 33-14-33-400-001
Installation of the Annunciator-Light Test and Interface-Board
3. Fault Confirmation
Subtask 33-14-00-710-058-A ** ON A/C NOT FOR ALL
A. Do the operational test of the cockpit and cabin temperature control with CFDS/MCDU AMM 21-63-00-710-004.
4. Fault Isolation
Subtask 33-14-00-810-060-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message P2 FAULT RELAY (20LP):
   (1) If the fault continues:
  • do a check and repair the wiring between pin AB/8B of the air-conditioning system controller 2 (57HH) and pin A/2 of the annunciator-light test and interface-board (20LP) ASM 215101.
Subtask 33-14-00-710-059-A ** ON A/C NOT FOR ALL
B. Do the operational test of the cockpit and cabin temperature control with CFDS/MCDU AMM 21-63-00-710-004.
[Rev.8 from Aug 2018] 2026.04.04 04:31:54 UTC