Failure of One Annunciator Light Only
TASK 33-14-00-810-801-A
Failure of One Annunciator Light Only
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 33-14-00-710-050-A 4. Fault Isolation
Subtask 33-14-00-810-050-A
[Rev.8 from Aug 2018]
2026.04.04 04:39:08 UTC
Failure of One Annunciator Light Only
1. Possible Causes
- lamp
- annunciator-light test and interface-board
- wiring
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 33-14-00-710-001 | Operational Test of the Lights |
| ASM 331402 | |
| AMM 33-14-33-000-001 | Removal of the Annunciator-Light Test and Interface-Board |
| AMM 33-14-33-400-001 | Installation of the Annunciator-Light Test and Interface-Board |
Subtask 33-14-00-710-050-A 4. Fault Isolation
Subtask 33-14-00-810-050-A
A. If one annunciator light is off during the test:
Subtask 33-14-00-710-051-A - Replace the related lamp .
- Replace the related annunciator-light test and interface-board AMM 33-14-33-000-001 and AMM 33-14-33-400-001.
- Do a check and repair the related wiring ASM 331402.
B. Do the test given in Para. 3.
Annunciator Light Test and Dimming