Failure of the Captain and First-Officer Supplementary Reading-Lights
TASK 33-12-00-810-822-A
Failure of the Captain and First-Officer Supplementary Reading-Lights
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 33-12-00-710-092-A
Subtask 33-12-00-810-088-A
[Rev.8 from Aug 2018]
2026.04.04 04:31:53 UTC
Failure of the Captain and First-Officer Supplementary Reading-Lights
1. Possible Causes
- wiring
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 33-12-00-710-001 | Operational Test of the General Illumination |
| ASM 331202 |
Subtask 33-12-00-710-092-A
A. Test
(1) Do the operational test of the general illumination AMM 33-12-00-710-001.
4. Fault Isolation(1) Do the operational test of the general illumination AMM 33-12-00-710-001.
NOTE: Do this test for the supplementary reading lights (29LE) only.
Subtask 33-12-00-810-088-A
A. If during the operational test, on the Captain and the F/O side:
(1) On the reading light panel 54VU:
The supplementary reading lights (29LE) do not come on when you turn the READING LT potentiometers from the OFF position to the BRT position.
Subtask 33-12-00-710-093-A (1) On the reading light panel 54VU:
The supplementary reading lights (29LE) do not come on when you turn the READING LT potentiometers from the OFF position to the BRT position.
- Repair the wiring between pin 2 of the instrument-panel flood-lighting control-circuit-breaker (2LE) and the first terminal block ASM 331202.
B. Do the test given in Para. 3.