W DOC AIRBUS | TSM A320F

Failure of the F/O Map Table Light


TASK 33-12-00-810-821-A
Failure of the F/O Map Table Light


1. Possible Causes
  • RHEOSTAT-MAP TABLE LIGHT,F/O [40LE]
  • LIGHT-MAP TABLE, F/O [42LE]
  • wiring
  • CTL BOX-MAP TABLE LT, F/O [54LE]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 33-12-00-710-001
Operational Test of the General Illumination
AIPC 331201
ASM 331201
AMM 33-12-12-000-804
Removal of the Map Table Light
AMM 33-12-12-400-804
Installation of the Map Table Light
AMM 33-12-18-000-802
Removal of the Map-Table Light Control-Box
AMM 33-12-18-400-802
Installation of the Map-Table Light Control-Box
3. Fault Confirmation
Subtask 33-12-00-710-090-A
A. Test
Do the operational test of the general illumination AMM 33-12-00-710-001.
NOTE: Do this test for the instrument lighting, the supplementary reading lights, the map table lights and the center pedestal light only.
4. Fault Isolation
Subtask 33-12-00-810-071-A ** ON A/C NOT FOR ALL
A. If, during the operational test:
   (1) The dimming function of the F/O map table light rheostat is not operative:
   (2) The F/O map table light does not come on:
  • make sure that there is 28VDC at the F/O map table light rheostat (40LE) pin A ASM 331201.
     (a) If there is 28VDC:
       1 If the fault continues:
  • repair the wiring between the F/O map table light (42LE) and the related rheostat (40LE) ASM 331201.
     (b) If there is no 28VDC:
       1 If the fault continues:
  • do a check of the wiring from the F/O map table light rheostat (40LE) pin 1 to the first terminal block ASM 331201.
         a If the fault continues:
  • repair the wiring from the F/O map table light rheostat (40LE) pin 2 to the ground terminal block ASM 331201.
Subtask 33-12-00-810-071-C ** ON A/C NOT FOR ALL
A. If, during the operational test:
   (1) The dimming function of the F/O map table light does not operate correctly:
   (2) The F/O map-table light (42LE) does not come on:
  • Make sure that there is 28VDC at pin 1 of the receptacle of the F/O map-table-light control-box (54LE) ASM 331201.
     (a) If there is no 28VDC:
  • Repair the wiring .
     (b) If there is 28VDC:
  • Do a check for a ground signal at ASM 331201:
    - Pin 3 of the receptacle of the F/O map-table-light control-box (54LE)
    - Pin 2 of the receptacle of the F/O map-table-light control-box (54LE).
       1 If there is no ground signal:
  • Repair the wiring .
       2 If the fault continues:
         a If the fault continues:
Subtask 33-12-00-710-091-A
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:31:53 UTC