Failure of the CAPT Map Table Light
TASK 33-12-00-810-820-A
Failure of the CAPT Map Table Light
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 33-12-00-710-088-A ** ON A/C NOT FOR ALL
Subtask 33-12-00-810-070-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:31:52 UTC
Failure of the CAPT Map Table Light
1. Possible Causes
- RHEOSTAT-MAP TABLE LIGHT,CAPT [39LE]
- LIGHT-MAP TABLE, CAPT [41LE]
- wiring
- CTL BOX-MAP TABLE LT, CAPT [53LE]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 33-12-00-710-001 | Operational Test of the General Illumination |
| AIPC 331201 | |
| ASM 331201 | |
| AMM 33-12-12-000-804 | Removal of the Map Table Light |
| AMM 33-12-12-400-804 | Installation of the Map Table Light |
| AMM 33-12-18-000-802 | Removal of the Map-Table Light Control-Box |
| AMM 33-12-18-400-802 | Installation of the Map-Table Light Control-Box |
Subtask 33-12-00-710-088-A ** ON A/C NOT FOR ALL
A. Test
Do the operational test of the general illumination AMM 33-12-00-710-001.
4. Fault IsolationDo the operational test of the general illumination AMM 33-12-00-710-001.
NOTE: Do this test for the instrument lighting, the supplementary reading lights, the map table lights and the center pedestal light only.
Subtask 33-12-00-810-070-A ** ON A/C NOT FOR ALL
A. If, during the operational test:
(1) The dimming function of the CAPT map table light does not operate correctly:
Subtask 33-12-00-810-070-C ** ON A/C NOT FOR ALL (1) The dimming function of the CAPT map table light does not operate correctly:
- replace the RHEOSTAT-MAP TABLE LIGHT,CAPT [39LE] AIPC 331201.
- make sure that there is 28VDC at the CAPT map table light rheostat (39LE) pin A ASM 331201.
- replace the LIGHT-MAP TABLE, CAPT [41LE] AIPC 331201.
- repair the wiring between the CAPT map table light (41LE) and the related rheostat (39LE) ASM 331201.
- replace the RHEOSTAT-MAP TABLE LIGHT,CAPT [39LE] AIPC 331201.
- do a check of the wiring from the CAPT map table light rheostat (39LE) pin 1 to the first terminal block ASM 331201.
- repair the wiring from the CAPT map table light rheostat (39LE) pin 2 to the ground terminal block ASM 331201.
A. If, during the operational test:
(1) The dimming function of the F/O map table light does not operate correctly:
Subtask 33-12-00-710-089-A ** ON A/C NOT FOR ALL (1) The dimming function of the F/O map table light does not operate correctly:
- Replace CTL BOX-MAP TABLE LT, CAPT [53LE] AMM 33-12-18-000-802 and AMM 33-12-18-400-802.
- Make sure that there is 28VDC at pin 1 of the receptacle of the Captain map-table-light control-box (53LE) ASM 331201.
- Repair the wiring .
- Do a check for a ground signal at ASM 331201:
- Pin 3 of the receptacle of the Captain map-table-light control-box (53LE)
- Pin 2 of the receptacle of the Captain map-table-light control-box (53LE)
- Repair the wiring .
- Replace CTL BOX-MAP TABLE LT, CAPT [53LE] AMM 33-12-18-000-802 and AMM 33-12-18-400-802.
- Replace LIGHT-MAP TABLE, CAPT [41LE] AMM 33-12-12-000-804 and AMM 33-12-12-400-804.
B. Do the test given in Para. 3.