W DOC AIRBUS | TSM A320F

Cockpit Outlet Failure


TASK 33-12-00-810-819-A
Cockpit Outlet Failure


1. Possible Causes
  • OUTLET COCKPIT (32LE)
  • wiring
  • OUTLET COCKPIT (31LE)
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ASM 331202
AIPC 331208
3. Fault Confirmation
Subtask 33-12-00-710-086-A
A. Test
On the panel 122VU, do a check of:
  • 28VDC at the cockpit outlet (32LE)
  • 115VAC at the cockpit outlet (31LE) ASM 331202.
4. Fault Isolation
Subtask 33-12-00-810-068-A
A. If there is not 28VDC at the cockpit outlet (32LE)
   (1) If the fault continues:
  • do a check and repair the related wiring from the cockpit outlet (32LE):
    . pin 1 to the first terminal block
    . pin N to the ground terminal AIPC 331208
  • go to Para. 4.C.
Subtask 33-12-00-810-069-A
B. If there is not 115VAC at the cockpit outlet (31LE):
   (1) If the fault continues:
  • do a check and repair the related wiring from the cockpit outlet (31LE):
    . pin 1 to the first terminal block
    . pin W to the ground terminal
    . pin GR to the ground terminal AIPC 331208
  • go to Para. 4.C.
Subtask 33-12-00-710-087-A
C. Do the test given in Para. 3.