Failure of the Instrument Panel Flood-Lighting
TASK 33-12-00-810-818-A
Failure of the Instrument Panel Flood-Lighting
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 33-12-00-710-084-B
Subtask 33-12-00-810-067-A
[Rev.8 from Aug 2018]
2026.04.04 04:31:52 UTC
Failure of the Instrument Panel Flood-Lighting
1. Possible Causes
- C/B-LIGHTING/FLOOD/CTR INST/PNL [2LE]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 33-12-00-710-001 | Operational Test of the General Illumination |
| ASM 331202 |
Subtask 33-12-00-710-084-B
A. Test
Do the operational test of the general illumination AMM 33-12-00-710-001.
4. Fault IsolationDo the operational test of the general illumination AMM 33-12-00-710-001.
NOTE: Do this test for the instrument lighting, the supplementary reading lights, the map table lights and the center pedestal light only.
Subtask 33-12-00-810-067-A
A. If during the operational test, the supplementary reading lights (29LE), the First Officer main instrument-panel light (36LE) and one of the center main instrument-panel lights (38LE) do not come on:
Subtask 33-12-00-710-085-A - replace the C/B-LIGHTING/FLOOD/CTR INST/PNL [2LE] ASM 331202.
B. Do the test given in Para. 3.