W DOC AIRBUS | TSM A320F

Failure of the Instrument Panel Flood-Lighting


TASK 33-12-00-810-818-A
Failure of the Instrument Panel Flood-Lighting


1. Possible Causes
  • C/B-LIGHTING/FLOOD/CTR INST/PNL [2LE]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 33-12-00-710-001
Operational Test of the General Illumination
ASM 331202
3. Fault Confirmation
Subtask 33-12-00-710-084-B
A. Test
Do the operational test of the general illumination AMM 33-12-00-710-001.
NOTE: Do this test for the instrument lighting, the supplementary reading lights, the map table lights and the center pedestal light only.
4. Fault Isolation
Subtask 33-12-00-810-067-A
A. If during the operational test, the supplementary reading lights (29LE), the First Officer main instrument-panel light (36LE) and one of the center main instrument-panel lights (38LE) do not come on:
Subtask 33-12-00-710-085-A
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:31:52 UTC