Failure of the Center Pedestal Light
TASK 33-12-00-810-815-A
Failure of the Center Pedestal Light
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 33-12-00-710-078-B ** ON A/C NOT FOR ALL
Subtask 33-12-00-810-064-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:31:52 UTC
Failure of the Center Pedestal Light
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 331200 | |
| AMM 33-12-00-710-001 | Operational Test of the General Illumination |
| ASM 331202 | |
| AIPC 331208 | |
| AMM 33-12-14-000-002 | Removal of the Center Pedestal Light |
| AMM 33-12-14-400-002 | Installation of the Center Pedestal Light |
| AMM 33-12-17-000-802 | Removal of the Flood-Light Control Boxes |
| AMM 33-12-17-400-802 | Installation of the Flood-Light Control Boxes |
Subtask 33-12-00-710-078-B ** ON A/C NOT FOR ALL
A. Test
Do the operational test of the general illumination AMM 33-12-00-710-001.
Subtask 33-12-00-710-078-C ** ON A/C NOT FOR ALL Do the operational test of the general illumination AMM 33-12-00-710-001.
NOTE: Do this test for the instrument lighting, the supplementary reading lights, the map table lights and the center pedestal light only.
A. Test
Do the operational test of the general illumination AMM 33-12-00-710-001.
4. Fault IsolationDo the operational test of the general illumination AMM 33-12-00-710-001.
NOTE: Do this test for the center pedestal light only.
Subtask 33-12-00-810-064-A ** ON A/C NOT FOR ALL
A. If during the operational test:
(1) The FLOOD LT/PED rheostat (28LE) is inoperative on the related center pedestal light (27LE):
Subtask 33-12-00-810-064-B ** ON A/C NOT FOR ALL (1) The FLOOD LT/PED rheostat (28LE) is inoperative on the related center pedestal light (27LE):
- replace the RHEOSTAT FLOOD LT/PED [28LE] AIPC 331208.
- remove the LT-CENTER PEDESTAL [27LE] AMM 33-12-14-000-002
- make sure that there is 28VDC at the lamp socket.
- replace the defective lamp AMM 33-12-14-400-002.
- do a check for continuity between pin A/1 and pin A/2 of the pedestal flood light rheostat (28LE).
- replace the RHEOSTAT FLOOD LT/PED [28LE] AIPC 331208.
- do a check for 28VDC at pin A/1 of the pedestal flood light rheostat (28LE) ASM 331202.
- do a check and repair the wiring between the pedestal flood light rheostat (28LE) pin A/1 and the first terminal block ASM 331202.
- do a check and repair the wiring between the center pedestal light (27LE):
. and the pedestal flood light rheostat (28LE)
. and the ground terminal ASM 331202.
A. If during the operational test:
(1) On the panel overhead control and indicating panel 48VU:
Subtask 33-12-00-710-079-A (1) On the panel overhead control and indicating panel 48VU:
- The center pedestal light does not come on when you turn the FLOOD LT/PED potentiometer from the OFF position to the BRT position.
- Do a check for a ground signal at pin 2 of the center pedestal light (27LE) ASM 331202.
- Repair the wiring between the pin 2 of the center pedestal light (27LE) and the ground.
- Do a check for continuity between the pin 1 of the center pedestal light (27LE) and the pin A/2 of the flood light/pedestal single control-box (50LE) ASM 331202.
- Repair the wiring .
- Do a check for 28VDC at pin 1 of the receptacle of the flood light/pedestal single control-box (50LE) ASM 331200.
- Repair the wiring .
- Do a check for a ground signal at pin A/3 of the receptacle of the flood light/pedestal single control-box (50LE) ASM 331200.
* If there is no ground signal:
* - Repair the wiring between pin A/3 of the receptacle of the reading-light single control-box (51LE) and the ground terminal.
* If there is ground signal:
* - Replace LT-CENTER PEDESTAL [27LE] AMM 33-12-14-000-002 and AMM 33-12-14-400-002.
** If the fault continues:
* - Replace CTL BOX-SINGLE, FLOOD LT/PED [50LE] AMM 33-12-17-000-802 and AMM 33-12-17-400-802.
B. Do the test given in Para. 3.