W DOC AIRBUS | TSM A320F

Failure of the First Officer Seat, Console and Briefcase Lights


TASK 33-12-00-810-806-A
Failure of the First Officer Seat, Console and Briefcase Lights


1. Possible Causes
  • SW-CONSOLE/FLOOR (16LE)
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 33-12-00-710-001
Operational Test of the General Illumination
ASM 331201
AWM 331202
AIPC 331208
3. Fault Confirmation
Subtask 33-12-00-710-060-A
A. Test
Do the operational test of the general illumination AMM 33-12-00-710-001.
NOTE: Do this test for the console and briefcase lights only.
4. Fault Isolation
Subtask 33-12-00-810-055-A
A. If, during the operational test, the First Officer seat, console and briefcase lights do not operate correctly
   (1) When the CONSOLE/FLOOR switch (16LE) is in the DIM position:
     (a) If the fault continues:
  • do a check and repair the wiring from the CONSOLE/FLOOR switch (16LE) pin 2D to the first terminal block ASM 331201.
   (2) When the CONSOLE/FLOOR switch (16LE) is in the BRT position:
  • do a check and repair the wiring from the circuit breaker (4LE) to the first terminal block, via the CONSOLE/FLOOR switch (16LE) AWM 331202 .
Subtask 33-12-00-710-061-A
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:31:52 UTC