Loss of the ADIRU Buses that Supply the BSCU
TASK 32-51-00-810-832-A
Loss of the ADIRU Buses that Supply the BSCU
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 32-51-00-740-113-A ** ON A/C NOT FOR ALL
Subtask 32-51-00-810-090-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:31:50 UTC
Loss of the ADIRU Buses that Supply the BSCU
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 31-32-00-860-009 | Procedure to Get Access to the SYSTEM REPORT/TEST/L/G Page |
| ASM 324202 | |
| AMM 32-42-34-000-001 | Removal of the Braking/Steering Control Unit (BSCU) |
| AMM 32-42-34-400-001 | Installation of the Braking/Steering Control Unit (BSCU) |
| AMM 32-46-00-740-001 | BITE Test of the BSCU |
| AMM 32-46-00-740-002 | BITE Test of the BSCU - Ground Scanning |
| AMM 34-12-34-000-001 | Removal of the ADIRU |
| AMM 34-12-34-400-001 | Installation of the ADIRU |
| AMM 34-14-00-740-004 | SYSTEM TEST of the Inertial Reference (IR) |
Subtask 32-51-00-740-113-A ** ON A/C NOT FOR ALL
A. Test
(1) Do a check of the Post Flight Report (PFR) and make sure that the fault is shown.
(2) Get access to the SYSTEM REPORT/TEST/L/G page for BSCU1 and BSCU2 AMM 31-32-00-860-009.
(3) Make sure that the TROUBLE SHOOTING DATA (TSD) gives fault code 7C.
(a) If the fault occurred during flight phase 1, do the BITE test of the BSCU AMM 32-46-00-740-001.
1 If the fault continues, do the Para. Fault Isolation.
(b) If the fault occurred during flight phases 2 to 9, do the Para. Fault Isolation.
Subtask 32-51-00-740-113-B ** ON A/C NOT FOR ALL (1) Do a check of the Post Flight Report (PFR) and make sure that the fault is shown.
(2) Get access to the SYSTEM REPORT/TEST/L/G page for BSCU1 and BSCU2 AMM 31-32-00-860-009.
| ACTION | RESULT |
|---|---|
|
|
|
|
(a) If the fault occurred during flight phase 1, do the BITE test of the BSCU AMM 32-46-00-740-001.
1 If the fault continues, do the Para. Fault Isolation.
(b) If the fault occurred during flight phases 2 to 9, do the Para. Fault Isolation.
A. Test
(1) Do a check of the Post Flight Report (PFR) and make sure that the fault is shown.
(2) Get access to the SYSTEM REPORT/TEST/L/G page for BSCU1 and BSCU2 AMM 31-32-00-860-009.
(3) Make sure that the TROUBLE SHOOTING DATA (TSD) gives fault code 968, 972, 976, 980 or 984.
(a) If the fault occurred during flight phase 1, do the BITE test of the BSCU (GROUND SCANNING) AMM 32-46-00-740-002.
1 If the fault continues, do the Para. Fault Isolation.
(b) If the fault occurred during flight phases 2 to 9, do the Para. Fault Isolation.
4. Fault Isolation(1) Do a check of the Post Flight Report (PFR) and make sure that the fault is shown.
(2) Get access to the SYSTEM REPORT/TEST/L/G page for BSCU1 and BSCU2 AMM 31-32-00-860-009.
| ACTION | RESULT |
|---|---|
|
|
|
|
(a) If the fault occurred during flight phase 1, do the BITE test of the BSCU (GROUND SCANNING) AMM 32-46-00-740-002.
1 If the fault continues, do the Para. Fault Isolation.
(b) If the fault occurred during flight phases 2 to 9, do the Para. Fault Isolation.
Subtask 32-51-00-810-090-A ** ON A/C NOT FOR ALL
A. If there is the fault message BSCU: ADIRU 1, 2, 3:
(1) Do the BITE test (System Test) of IR1, IR2 and IR3 AMM 34-14-00-740-004.
(a) If the test gives a fault message related to ADIRU-1 [1FP1] , ADIRU-2 [1FP2] or ADIRU-3 [1FP3] :
Subtask 32-51-00-810-090-B ** ON A/C NOT FOR ALL (1) Do the BITE test (System Test) of IR1, IR2 and IR3 AMM 34-14-00-740-004.
(a) If the test gives a fault message related to ADIRU-1 [1FP1] , ADIRU-2 [1FP2] or ADIRU-3 [1FP3] :
- Replace the related ADIRU AMM 34-12-34-000-001 and AMM 34-12-34-400-001.
- Replace the BSCU [10GG] AMM 32-42-34-000-001 and AMM 32-42-34-400-001.
- Do a check and repair the wiring ASM 324202 if necessary between:
* Pins AA/11J, 11H of the BSCU (10GG) and the first terminal block
* Pins AA/10J, 10H of the BSCU (10GG) and the first terminal block
* Pins AA/12J, 12H of the BSCU (10GG) and the first terminal block
* Pins AA/12B, 12C of the BSCU (10GG) and the first terminal block.
A. If there is the fault message ADIRU 1+2+3(1FP1+2+3)/BSCU(10GG):
(1) Do the BITE test (System Test) of IR1, IR2 and IR3 AMM 34-14-00-740-004.
(a) If the test gives a fault message related to ADIRU-1 [1FP1] , ADIRU-2 [1FP2] or ADIRU-3 [1FP3] :
(1) Do the BITE test (System Test) of IR1, IR2 and IR3 AMM 34-14-00-740-004.
(a) If the test gives a fault message related to ADIRU-1 [1FP1] , ADIRU-2 [1FP2] or ADIRU-3 [1FP3] :
- Replace the related ADIRU AMM 34-12-34-000-001 and AMM 34-12-34-400-001.
- Replace the BSCU [10GG] AMM 32-42-34-000-001 and AMM 32-42-34-400-001.
- Do a check and repair the wiring ASM 324202 if necessary between:
* Pins AA/11J, 11H of the BSCU (10GG) and the first terminal block
* Pins AA/10J, 10H of the BSCU (10GG) and the first terminal block
* Pins AA/12J, 12H of the BSCU (10GG) and the first terminal block
* Pins AA/12B, 12C of the BSCU (10GG) and the first terminal block.