Loss of the ENG 2 OIL LOW PRESS Signal from the Relay to the TPIS
TASK 32-49-00-810-821-A
Loss of the ENG 2 OIL LOW PRESS Signal from the Relay to the TPIS
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 32-49-00-865-054-A
Subtask 32-49-00-810-070-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:31:47 UTC
Loss of the ENG 2 OIL LOW PRESS Signal from the Relay to the TPIS
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 32-49-00-710-001 | Operational Test of the Tire Pressure Indicating System (TPIS) |
| ASM 324901 | |
| AMM 32-49-34-000-001 | Removal of the TPIS Detection Unit |
| AMM 32-49-34-400-001 | Installation of the TPIS Detection Unit |
| ASM 761201 | |
| ASM 793601 |
Subtask 32-49-00-865-054-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 32-49-00-710-091-A ** ON A/C NOT FOR ALL 4. Fault Isolation| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | ENGINE/ENG2/OIL/PRESS | 2EN2 | N42 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | OIL/PRESS/ENG2 | 10KC2 | N42 |
Subtask 32-49-00-810-070-A ** ON A/C NOT FOR ALL
A. If the operational test gives the maintenance message CHECK OIL PRESS SWITCH 3EN2:
- Do a check and repair the:
. wiring from the circuit breaker (2EN2) to the relay (3EN2) pin A/X
. wiring from the relay (3EN2) pin A/Z to the control switch (2KC) pin 3A ASM 793601.
Subtask 32-49-00-810-070-D ** ON A/C NOT FOR ALL - Replace the RELAY-ENG2 OIL LOW PRESS [3EN2] .
- Replace the
[2GV] AMM 32-49-34-000-001 and AMM 32-49-34-400-001.
- Do a check of the wiring from the TPIS (2GV) pin AB/12A to the relay (3EN2) pin A/6 ASM 324901.
- Repair the related wiring.
- Replace the CTL SW-ENG/MASTER 2 [2KC] .
- Do a check and repair the:
. wiring from the circuit breaker (2EN2) to the relay (3EN2) pin A/X
. wiring from the relay (3EN2) pin A/Z to the control switch (2KC) pin 3A ASM 793601.
A. If the operational test gives the maintenance message CHECK OIL PRESS SWITCH 3EN2:
Subtask 32-49-00-710-092-A ** ON A/C NOT FOR ALL NOTE: The FIN of the relay given in this fault message is not correct. In the NEO configuration, relay 11KC2 replaces relay 3EN2.
- Replace the RELAY-ENG2 OIL PRESS [11KC2] .
- Replace the
[2GV] AMM 32-49-34-000-001 and AMM 32-49-34-400-001.
- Do a check of the wiring ASM 324901 between:
. the TPIS (2GV) pin AB/12A and the relay (11KC2) pin A/6
. the relay (11KC2) pin A/C and the ground.
- Repair the related wiring.
- Replace the CTL SW-ENG/MASTER 2 [2KC] .
- Do a check and repair the wiring ASM 761201 between:
. the circuit breaker (10KC2) and the relay (11KC2) pin A/X
. the relay (11KC2) pin A/Z and the control switch (2KC) pin 3A
. the control switch (2KC) pin 1A and the ground.
B. Do the test given in Para. 3.B.