Brake Fans Inoperative on the Wheel 3 #amp# 4
TASK 32-48-00-810-803-A
Brake Fans Inoperative on the Wheel 3 & 4
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 32-48-00-710-054-A ** ON A/C NOT FOR ALL
Subtask 32-48-00-810-052-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:31:47 UTC
Brake Fans Inoperative on the Wheel 3 & 4
1. Possible Causes
wiring between the right brake fan contactor (6GS) at pins A/A1, B1, C1 and the first terminal block wiring from the right brake fan contactor (6GS) pin A/X2 to the first terminal block wiring from the right brake fan contactor (6GS) pin A/X1 to the first terminal block CONTACTOR-BRK FAN, R (6GS) wiring from the right brake fan contactor (6GS) to the circuit breaker (2GS) - C/B-HYDRAULIC/BRK FAN/WHEELS/3 AND 4 [2GS]
- MOTOR ASSY-BRK FAN,WHEEL AXLE 4 [10GS]
- MOTOR ASSY-BRK FAN,WHEEL AXLE 3 [8GS]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 32-48-00-710-001 | Functional Test of The Brake Cooling System |
| ASM 324801 | |
| AMM 32-48-51-000-005 | Removal of the Fan Assy |
| AMM 32-48-51-400-005 | Installation of the Fan Assy |
Subtask 32-48-00-710-054-A ** ON A/C NOT FOR ALL
A. Test
(1) Do the operational test of the brake cooling system AMM 32-48-00-710-001.
(a) If the circuit breaker (2GS) trips:
4. Fault Isolation(1) Do the operational test of the brake cooling system AMM 32-48-00-710-001.
(a) If the circuit breaker (2GS) trips:
- Refer to Para. 4.A.(2).
Subtask 32-48-00-810-052-A ** ON A/C NOT FOR ALL
A. If the test confirms the fault:
Subtask 32-48-00-710-055-A ** ON A/C NOT FOR ALL - Do a check of the circuit breaker (2GS) status.
- Do a check for 115VAC at pins A/A1, B1, C1 of the right brake fan contactor (6GS) ASM 324801.
- Do a check of the
wiring between the right brake fan contactor (6GS) at pins A/A1, B1, C1 and the first terminal block ASM 324801.
- Repair the related wiring.
- Do a check for a ground signal at pin A/X2 of the right brake fan contactor (6GS) ASM 324801.
- Repair the
wiring from the right brake fan contactor (6GS) pin A/X2 to the first terminal block ASM 324801.
- Do a check and repair the
wiring from the right brake fan contactor (6GS) pin A/X1 to the first terminal block ASM 324801.
- Replace the
CONTACTOR-BRK FAN, R (6GS) .
- Do a check of the
wiring from the right brake fan contactor (6GS) to the circuit breaker (2GS) : pins A/A2, B2, C2 to pins A2, B2, C2 ASM 324801.
- Repair the related wiring.
- Replace the C/B-HYDRAULIC/BRK FAN/WHEELS/3 AND 4 [2GS] .
- Close the circuit breaker.
- Replace the
CONTACTOR-BRK FAN, R (6GS) or MOTOR ASSY-BRK FAN,WHEEL AXLE 4 [10GS] or MOTOR ASSY-BRK FAN,WHEEL AXLE 3 [8GS] ,
AMM 32-48-51-000-005 and AMM 32-48-51-400-005.
- Do a check for a short to ground at:
. the wiring from the circuit breaker (2GS) to the right brake fan contactor (6GS): pins A2, B2, C2 to pins A/A2, B2, C2
. the wiring from the right brake fan contactor (6GS) pins A/A1, B1, C1 to the wheel axle 4, brake- fan motor assy (10GS) pin A/1,2,3.
. the wiring from the right brake fan contactor (6GS) pins A/A1, B1, C1 to the wheel axle 3, brake- fan motor assy (8GS) pin A/1,2,3.
ASM 324801.
- Repair the related wiring.
- Replace the C/B-HYDRAULIC/BRK FAN/WHEELS/3 AND 4 [2GS] .
- Replace the
CONTACTOR-BRK FAN, R (6GS) .
B. Test
Do the test given in Para. 3.A.(1).
Do the test given in Para. 3.A.(1).