W DOC AIRBUS | TSM A320F

Brake Fans Inoperative on the Wheel 3 #amp# 4


TASK 32-48-00-810-803-A
Brake Fans Inoperative on the Wheel 3 & 4


1. Possible Causes
  • wiring between the right brake fan contactor (6GS) at pins A/A1, B1, C1 and the first terminal block
  • wiring from the right brake fan contactor (6GS) pin A/X2 to the first terminal block
  • wiring from the right brake fan contactor (6GS) pin A/X1 to the first terminal block
  • CONTACTOR-BRK FAN, R (6GS)
  • wiring from the right brake fan contactor (6GS) to the circuit breaker (2GS)
  • C/B-HYDRAULIC/BRK FAN/WHEELS/3 AND 4 [2GS]
  • MOTOR ASSY-BRK FAN,WHEEL AXLE 4 [10GS]
  • MOTOR ASSY-BRK FAN,WHEEL AXLE 3 [8GS]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 32-48-00-710-001
Functional Test of The Brake Cooling System
ASM 324801
AMM 32-48-51-000-005
Removal of the Fan Assy
AMM 32-48-51-400-005
Installation of the Fan Assy
3. Fault Confirmation
Subtask 32-48-00-710-054-A ** ON A/C NOT FOR ALL
A. Test
   (1) Do the operational test of the brake cooling system AMM 32-48-00-710-001.
     (a) If the circuit breaker (2GS) trips:
  • Refer to Para. 4.A.(2).
   (2) Make sure that the fans do not operate on the right gear.
4. Fault Isolation
Subtask 32-48-00-810-052-A ** ON A/C NOT FOR ALL
A. If the test confirms the fault:
  • Do a check of the circuit breaker (2GS) status.
   (1) If the circuit breaker (2GS) is closed:
  • Do a check for 115VAC at pins A/A1, B1, C1 of the right brake fan contactor (6GS) ASM 324801.
     (a) If there is 115VAC:
  • Do a check of the wiring between the right brake fan contactor (6GS) at pins A/A1, B1, C1 and the first terminal block ASM 324801.
       1 If there is no continuity:
  • Repair the related wiring.
       2 If there is continuity:
  • Do a check for a ground signal at pin A/X2 of the right brake fan contactor (6GS) ASM 324801.
         a If there is no ground signal:
  • Repair the wiring from the right brake fan contactor (6GS) pin A/X2 to the first terminal block ASM 324801.
         b If there is a ground signal:
  • Do a check and repair the wiring from the right brake fan contactor (6GS) pin A/X1 to the first terminal block ASM 324801.
     (b) If there is no 115VAC:
  • Replace the CONTACTOR-BRK FAN, R (6GS).
       1 If the fault continues:
  • Do a check of the wiring from the right brake fan contactor (6GS) to the circuit breaker (2GS): pins A/A2, B2, C2 to pins A2, B2, C2 ASM 324801.
         a If there is no continuity:
  • Repair the related wiring.
         b If there is continuity:
  • Replace the C/B-HYDRAULIC/BRK FAN/WHEELS/3 AND 4 [2GS] .
   (2) If the circuit breaker (2GS) is open:
  • Close the circuit breaker.
     (a) If the circuit breaker trips:
       1 If the fault continues:
  • Do a check for a short to ground at:
    . the wiring from the circuit breaker (2GS) to the right brake fan contactor (6GS): pins A2, B2, C2 to pins A/A2, B2, C2
    . the wiring from the right brake fan contactor (6GS) pins A/A1, B1, C1 to the wheel axle 4, brake- fan motor assy (10GS) pin A/1,2,3.
    . the wiring from the right brake fan contactor (6GS) pins A/A1, B1, C1 to the wheel axle 3, brake- fan motor assy (8GS) pin A/1,2,3.
    ASM 324801.
         a If there is a short to ground:
  • Repair the related wiring.
         b If there is no short to ground:
  • Replace the C/B-HYDRAULIC/BRK FAN/WHEELS/3 AND 4 [2GS] .
     (b) If the circuit breaker (2GS) stays closed and if the fault continues:
  • Replace the CONTACTOR-BRK FAN, R (6GS).
Subtask 32-48-00-710-055-A ** ON A/C NOT FOR ALL
B. Test
Do the test given in Para. 3.A.(1).
[Rev.8 from Aug 2018] 2026.04.04 04:31:47 UTC