W DOC AIRBUS | TSM A320F

Loss of or Incorrect Brake Temperature Indication on Wheels 1, 2, 3 and 4


TASK 32-47-00-810-807-A
Loss of or Incorrect Brake Temperature Indication on Wheels 1, 2, 3 and 4


1. Possible Causes
  • wiring from the circuit breaker (1GW) to the first terminal block
  • C/B-HYDRAULIC/BRK/TEMP/DET/UNIT [1GW]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 32-46-00-740-001
BITE Test of the BSCU
ASM 324701
3. Fault Confirmation
Subtask 32-47-00-740-062-A
A. Test
   (1) Do a reset of the BSCU with the A/SKID AND NOSE WHEEL switch (5GG).
   (2) Do the BITE test of the BSCU AMM 32-46-00-740-001.
4. Fault Isolation
Subtask 32-47-00-810-056-C
A. If the test gives the maintenance messages BRAKE TEMP SENSOR1(5GW)/BTMU(3GW) and BRAKE TEMP SENSOR2(7GW)/BTMU(3GW) and BRAKE TEMP SENSOR3(4GW)/BTMU(2GW) and BRAKE TEMP SENSOR4(6GW)/BTMU(2GW) or if all wheel brake temperatures are equal to zero degrees:
  • Do a check of the circuit breaker (1GW) status.
   (1) If the circuit breaker is closed:
  • Do a check of the wiring from the circuit breaker (1GW) to the first terminal block ASM 324701.
     (a) If there is no continuity:
  • Repair the related wiring.
     (b) If there is continuity:
  • Replace the C/B-HYDRAULIC/BRK/TEMP/DET/UNIT [1GW] .
   (2) If the circuit breaker is open:
  • Close it.
     (a) If it trips:
  • Do a check of the wiring from the circuit breaker (1GW) to the first terminal block ASM 324701.
       1 If there is a short to ground:
  • Repair the related wiring.
       2 If there is no short to ground:
  • Replace the C/B-HYDRAULIC/BRK/TEMP/DET/UNIT [1GW] .
Subtask 32-47-00-740-063-A
B. Do the test given in Para. 3.A.