Loss of or Incorrect Brake Temperature Indication on Wheels 1, 2, 3 and 4
TASK 32-47-00-810-807-A
Loss of or Incorrect Brake Temperature Indication on Wheels 1, 2, 3 and 4
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 32-47-00-740-062-A
Subtask 32-47-00-810-056-C
[Rev.8 from Aug 2018]
2026.04.04 04:31:46 UTC
Loss of or Incorrect Brake Temperature Indication on Wheels 1, 2, 3 and 4
1. Possible Causes
wiring from the circuit breaker (1GW) to the first terminal block - C/B-HYDRAULIC/BRK/TEMP/DET/UNIT [1GW]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 32-46-00-740-001 | BITE Test of the BSCU |
| ASM 324701 |
Subtask 32-47-00-740-062-A
A. Test
(1) Do a reset of the BSCU with the A/SKID AND NOSE WHEEL switch (5GG).
(2) Do the BITE test of the BSCU AMM 32-46-00-740-001.
4. Fault Isolation(1) Do a reset of the BSCU with the A/SKID AND NOSE WHEEL switch (5GG).
(2) Do the BITE test of the BSCU AMM 32-46-00-740-001.
Subtask 32-47-00-810-056-C
A. If the test gives the maintenance messages BRAKE TEMP SENSOR1(5GW)/BTMU(3GW) and BRAKE TEMP SENSOR2(7GW)/BTMU(3GW) and BRAKE TEMP SENSOR3(4GW)/BTMU(2GW) and BRAKE TEMP SENSOR4(6GW)/BTMU(2GW) or if all wheel brake temperatures are equal to zero degrees:
Subtask 32-47-00-740-063-A - Do a check of the circuit breaker (1GW) status.
- Do a check of the
wiring from the circuit breaker (1GW) to the first terminal block ASM 324701.
- Repair the related wiring.
- Replace the C/B-HYDRAULIC/BRK/TEMP/DET/UNIT [1GW] .
- Close it.
- Do a check of the
wiring from the circuit breaker (1GW) to the first terminal block ASM 324701.
- Repair the related wiring.
- Replace the C/B-HYDRAULIC/BRK/TEMP/DET/UNIT [1GW] .
B. Do the test given in Para. 3.A.