W DOC AIRBUS | TSM A320F

Loss of the Brake Temperature Monitoring on Wheels 1 and 2


TASK 32-47-00-810-806-A
Loss of the Brake Temperature Monitoring on Wheels 1 and 2


1. Possible Causes
  • MONITORING UNIT-BRK TEMP, L [3GW]
  • wiring from the BTMU (3GW) pin A/A to the first terminal block
  • wiring from the BTMU (3GW) to the BSCU (10GG)
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 32-46-00-740-001
BITE Test of the BSCU
ASM 324701
AMM 32-47-18-000-001
Removal of the Brake Temperature Monitoring Unit
AMM 32-47-18-400-001
Installation of the Brake Temperature Monitoring Unit
3. Fault Confirmation
Subtask 32-47-00-740-060-A
A. Test
   (1) Do a reset of the BSCU with the A/SKID AND NOSE WHEEL switch (5GG).
   (2) Do the BITE test of the BSCU AMM 32-46-00-740-001.
4. Fault Isolation
Subtask 32-47-00-810-055-C
A. If the test gives the maintenance messages BRAKE TEMP SENSOR1(5GW)/BTMU(3GW) and BRAKE TEMP SENSOR2(7GW)/BTMU(3GW):
   (1) If the fault continues:
  • Do a check and repair the wiring from the BTMU (3GW) pin A/A to the first terminal block ASM 324701.
   (2) If the fault continues:
  • Do a check and repair the wiring from the BTMU (3GW) to the BSCU (10GG) pin A/B to pin AB/11C ASM 324701.
Subtask 32-47-00-740-061-A
B. Do the test given in Para. 3.A.