Loss of the Accumulator Yellow-Pressure Indication on the Triple Indicator (Electrical Failure)
TASK 32-44-00-810-805-A
Loss of the Accumulator Yellow-Pressure Indication on the Triple Indicator (Electrical Failure)
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 32-44-00-865-052-A
Subtask 32-44-00-810-054-A
Subtask 32-44-00-860-050-A
[Rev.8 from Aug 2018]
2026.04.04 04:31:43 UTC
Loss of the Accumulator Yellow-Pressure Indication on the Triple Indicator (Electrical Failure)
1. Possible Causes
- HYDR. PRESSURE TRANSMITTER [3068GN]
- IND-BRK YELLOW PRESS TRIPLE [60GG]
wiring from the pressure transducer (3068GN) pin A/F,B to the ground wiring from the pressure transducer (3068GN) to the triple indicator (60GG)
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 29-24-00-863-001 | Pressurize the Yellow Hydraulic System with the Electric Pump |
| AMM 29-24-00-864-001 | Depressurize the Yellow Hydraulic System |
| AMM 29-32-11-000-004 | Removal of the Hydraulic Pressure Transducer |
| AMM 29-32-11-400-004 | Installation of the Hydraulic Pressure Transducer |
| ASM 324401 | |
| AMM 32-44-21-000-001 | Removal of the Brake Yellow Pressure Triple Indicator |
| AMM 32-44-21-400-001 | Installation of the Brake Yellow Pressure Triple Indicator |
| AWM 324503 |
Subtask 32-44-00-865-052-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 32-44-00-860-052-A Subtask 32-44-00-700-050-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | L/G/Y BRK/PRESS/IND | 61GG | C10 |
| ** ON A/C NOT FOR ALL | |||
| 49VU | ABCU &/Y BRK/PRESS IND | 61GG | C10 |
C. Test
Make sure that there is no accumulator Yellow-pressure indication on the triple indicator.
4. Fault IsolationMake sure that there is no accumulator Yellow-pressure indication on the triple indicator.
Subtask 32-44-00-810-054-A
A. If the test confirms the fault:
Subtask 32-44-00-700-051-A - Replace the HYDR. PRESSURE TRANSMITTER [3068GN] AMM 29-32-11-000-004 and AMM 29-32-11-400-004.
- Replace the IND-BRK YELLOW PRESS TRIPLE [60GG] AMM 32-44-21-000-001 and AMM 32-44-21-400-001.
- Do a check for a ground signal at pins A/F, B of the pressure transducer (3068GN) ASM 324401.
- Repair the
wiring from the pressure transducer (3068GN) pin A/F,B to the ground ASM 324401.
- Do a check for continuity from the pressure transducer (3068GN) pin A/A to the terminal block (7528VT) pin 2/J AWM 324503.
- Repair the related wiring AWM 324503.
- Do a check and repair the
wiring from the pressure transducer (3068GN) to the triple indicator (60GG) : pins A/D, E to pins A/D, E ASM 324401.
B. Test
Make sure that there is an accumulator Yellow-pressure indication on the triple indicator.
5. Close-upMake sure that there is an accumulator Yellow-pressure indication on the triple indicator.
Subtask 32-44-00-860-050-A