Loss of the Yellow Pressure Indication on the Triple Indicator (Electrical Failure)
TASK 32-44-00-810-803-A
Loss of the Yellow Pressure Indication on the Triple Indicator (Electrical Failure)
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 32-44-00-710-055-A
Subtask 32-44-00-810-052-A
[Rev.8 from Aug 2018]
2026.04.04 04:31:43 UTC
Loss of the Yellow Pressure Indication on the Triple Indicator (Electrical Failure)
1. Possible Causes
- C/B-L/G/Y BRK/PRESS/IND or C/B-ABCU &/Y BRK/PRESS IND [61GG]
wiring from the terminal block (7528VT) pin 2/F to the circuit breaker (61GG).
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 324401 | |
| AWM 324401 |
Subtask 32-44-00-710-055-A
A. Test
(1) Do the operational test of the Alternate braking without anti skid.
(2) Make sure that there is no Yellow pressure indication on the triple indicator.
(a) If the circuit breaker (61GG) trips:
4. Fault Isolation(1) Do the operational test of the Alternate braking without anti skid.
(2) Make sure that there is no Yellow pressure indication on the triple indicator.
(a) If the circuit breaker (61GG) trips:
- refer to Para. 4.B.
Subtask 32-44-00-810-052-A
A. If the circuit breaker (61GG) is closed and if the test confirms the fault:
Subtask 32-44-00-710-056-A - do a check for 28VDC at pin 2/F of the terminal block (7528VT) AWM 324401.
- replace the C/B-L/G/Y BRK/PRESS/IND or C/B-ABCU &/Y BRK/PRESS IND [61GG] ASM 324401.
- do a check and repair the
wiring from the terminal block (7528VT) pin 2/F to the circuit breaker (61GG). .
B. Test
(1) Do the operational test of the Alternate braking without anti skid.
(2) Make sure that there is a Yellow pressure indication on the triple indicator.
(1) Do the operational test of the Alternate braking without anti skid.
(2) Make sure that there is a Yellow pressure indication on the triple indicator.