W DOC AIRBUS | TSM A320F

Failure of the left alternate braking system


TASK 32-43-00-810-827-A
Failure of the left alternate braking system


1. Possible Causes
  • SERVOVALVE-ALTN BRK, L [97GG]
  • PRESS XDCR-BRK, YELLOW L [101GG]
  • ABCU [95GG]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 29-24-00-863-001
Pressurize the Yellow Hydraulic System with the Electric Pump
AMM 31-32-00-860-009
Procedure to Get Access to the SYSTEM REPORT/TEST/L/G Page
AMM 32-43-00-710-002
Operational Check to start the Functional Test of the Alternate Braking Automatically (flight simulated)
AMM 32-43-34-000-001
Removal of the Alternate Braking Control Unit (ABCU)
AMM 32-43-34-400-001
Installation of the Alternate Braking Control Unit (ABCU)
AMM 32-43-35-000-001
Removal of the Alternate-Brake Direct Drive Valve
AMM 32-43-35-400-001
Installation of the Alternate-Brake Direct Drive Valve
AMM 32-44-19-000-001
Removal of the Pressure Transducer
AMM 32-44-19-400-001
Installation of the Pressure Transducer
TSM TASK 32-42-00-03
NORMAL BRAKING - TASK SUPPORTING DATA
3. Fault Confirmation
Subtask 32-43-00-740-072-A ** ON A/C NOT FOR ALL
A. Test
   (1) Do the operational check to start the functional test of the Alternate Braking automatically (flight simulated) AMM 32-43-00-710-002.
   (2) Read the TROUBLE SHOOTING DATA of the BSCU on the MCDU 32-42-00-03 TSM TASK 32-42-00-03.
4. Fault Isolation
Subtask 32-43-00-810-076-A ** ON A/C NOT FOR ALL
A. If the operational check gives the maintenance message ABCU(95GG)/BRK ALTN SERVOVALVE(97GG) and the TROUBLE SHOOTING DATA gives the fault code 1530:
   (1) Do these steps:
     (a) On the panel 400VU, make sure that the landing gear control lever is at DOWN.
     (b) Do a reset of the BSCU (10GG):
  • set the A/SKID & N/W STRG switch to OFF then to ON.
     (c) On the panel 110VU, make sure that the PARKING BRK control switch 73GG is at OFF.
     (d) Pressurize the Yellow hydraulic system AMM 29-24-00-863-001.
     (e) Set the PARKING BRK control switch 73GG to ON.
     (f) On the MCDU, get the system SYSTEM REPORT/TEST/L/G Page AMM 31-32-00-860-009.
     (g) On the SYSTEM REPORT/TEST/L/G Page, push the line key adjacent to the BSCU CHAN 1 (2) indication.
     (h) On the BSCU CHAN 1 (2) indication page, push the line key adjacent to the SPECIFIC DATA page 32-42-00-03 TSM TASK 32-42-00-03.
     (i) On the BSCU CHAN 1 (2) SPECIFIC DATA page, push the line key adjacent to the SYSTEM DATA indication.
     (j) On the SYSTEM DATA page, push the line key adjacent to the REFRESH indication.
     (k) Do a check of the Alternate Pressure Transducer Left (APTL) value page 1/3.
     (l) If the APTL pressure value is 145 +10 bar or -10 bar (2103.0467 +145.0377 psi or -145.0377 psi):
     (m) if the APTL pressure value is not equal to 145 +10 bar or -10 bar (2103.0467 +145.0377 psi or -145.0377 psi):
   (2) If the fault continues:
Subtask 32-43-00-740-073-A ** ON A/C NOT FOR ALL
B. Do the test given in Para.3.A.
[Rev.8 from Aug 2018] 2026.04.04 04:31:41 UTC