Failure of the BRK ALTN Selector Valve


TASK 32-43-00-810-821-A
Failure of the BRK ALTN Selector Valve


1. Possible Causes
  • SEL VALVE-ALTN BRK [99GG]
  • ABCU [95GG]
  • wiring.
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 32-43-00-710-002
Operational Check to start the Functional Test of the Alternate Braking Automatically (flight simulated)
ASM 324303
AMM 32-43-34-000-001
Removal of the Alternate Braking Control Unit (ABCU)
AMM 32-43-34-400-001
Installation of the Alternate Braking Control Unit (ABCU)
AMM 32-43-51-000-001
Removal of the Alternate Braking Selector Valve
AMM 32-43-51-400-001
Installation of the Alternate Braking Selector Valve
TSM TASK 32-42-00-03
NORMAL BRAKING - TASK SUPPORTING DATA
3. Fault Confirmation
Subtask 32-43-00-740-060-A ** ON A/C NOT FOR ALL
A. Test
   (1) Do the operational check to start the functional test of the Alternate Braking automatically (flight simulated) AMM 32-43-00-710-002.
   (2) Read the TROUBLE SHOOTING DATA of the BSCU on the MCDU 32-42-00-03 TSM TASK 32-42-00-03.
   (3) Print the TROUBLE SHOOTING DATA of the BSCU .
4. Fault Isolation
Subtask 32-43-00-810-070-A ** ON A/C NOT FOR ALL
A. If the operational check gives the maintenance message BRK ALTN SELECTOR VALVE(99GG) and the TROUBLE SHOOTING DATA gives the fault code 1590:
   (1) Do a check of the Alternate Pressure Transducer Left (APTL) and Alternate Pressure Transducer Right (APTR) pressure values 32-42-00-03 TSM TASK 32-42-00-03 printed in step 3.A.(3).
   (2) If one of these pressure values is more than 30 bar (435.1131 psi):
   (3) If the fault continues:
   (4) If the fault continues:
  • Do a check and repair the wiring. between the ABCU and the SEL VALVE-ALTN BRK ASM 324303
Subtask 32-43-00-740-061-A ** ON A/C NOT FOR ALL
B. Do the test given in Para.3.A.