Disagree between BSCU COM and MON for ground spoiler 2 signal
TASK 32-42-00-810-955-A
Disagree between BSCU COM and MON for ground spoiler 2 signal
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 32-42-00-740-210-A 4. Fault Isolation
Subtask 32-42-00-810-250-A
[Rev.8 from Aug 2018]
2026.04.04 04:31:39 UTC
Disagree between BSCU COM and MON for ground spoiler 2 signal
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 27-94-34-000-001 | Removal of the SEC |
| AMM 27-94-34-400-001 | Installation of the SEC |
| ASM 324203 | |
| AMM 32-42-34-000-001 | Removal of the Braking/Steering Control Unit (BSCU) |
| AMM 32-42-34-400-001 | Installation of the Braking/Steering Control Unit (BSCU) |
| AMM 32-46-00-740-005 | BITE Test of BSCU - Normal Braking TEST |
Subtask 32-42-00-740-210-A 4. Fault Isolation
Subtask 32-42-00-810-250-A
A. If the test gives the maintenance message SEC2 (1CE2)/BSCU (10GG):
Subtask 32-42-00-740-211-A - Replace the BSCU [10GG] AMM 32-42-34-000-001 AMM 32-42-34-400-001.
- Replace the SEC-2 [1CE2] AMM 27-94-34-000-001 AMM 27-94-34-400-001.
- Do a check and repair the
wiring between the BSCU (10GG) and the SEC2 (1CE2) ASM 324203.
B. Do the test given in Para.3.A.