W DOC AIRBUS | TSM A320F

Failure of the Normal Braking Pressure Transducer


TASK 32-42-00-810-944-A
Failure of the Normal Braking Pressure Transducer


1. Possible Causes
  • PRESS XDCR-NORM BRK SPLY [96GG]
  • wiring between the BSCU (10GG) and the Transducer (96GG)
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 32-42-22-000-001
Removal of the Normal-Brake Supply Pressure-Transducer
AMM 32-42-22-400-001
Installation of the Normal-Brake Supply Pressure-Transducer
AMM 32-46-00-740-001
BITE Test of the BSCU
3. Fault Confirmation
Subtask 32-42-00-740-200-A ** ON A/C NOT FOR ALL
A. Test
   (1) Do a reset of the BSCU with the A/SKID AND NOSE WHEEL switch (5GG).
   (2) Do the BITE test of the BSCU AMM 32-46-00-740-001.
4. Fault Isolation
Subtask 32-42-00-810-230-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message: BRK NORM SELECTOR VALVE PRESS TRANSDUCER(96GG)
   (1) If the fault continue:
  • do a check and repair the wiring between the BSCU (10GG) and the Transducer (96GG) pin AB/7E to pin A/D and pin AB/7F to pin A/E.
Subtask 32-42-00-740-201-A ** ON A/C NOT FOR ALL
B. Do the test given in Para.3.A.
[Rev.8 from Aug 2018] 2026.04.04 04:31:39 UTC