W DOC AIRBUS | TSM A320F

Failure of the normal brake servovalve relay (NSV1 + NSV3)


TASK 32-42-00-810-933-A
Failure of the normal brake servovalve relay (NSV1 + NSV3)


1. Possible Causes
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 32-42-00-710-001
Operational Check of the Normal Braking System
AMM 32-42-34-000-001
Removal of the Braking/Steering Control Unit (BSCU)
AMM 32-42-34-400-001
Installation of the Braking/Steering Control Unit (BSCU)
AMM 32-46-00-740-002
BITE Test of the BSCU - Ground Scanning
3. Fault Confirmation
Subtask 32-42-00-700-085-A
A. Test
   (1) Do the operational test of the normal braking system. AMM 32-42-00-710-001
   (2) Do the ground scanning of the BSCU during the operational test of the normal braking system. AMM 32-46-00-740-002
4. Fault Isolation
Subtask 32-42-00-810-216-A
A. If the test gives the maintenance messages BRK NORM SERVOVALVE 15GG and BRK NORM SERVOVALVE 16GG:
Subtask 32-42-00-700-086-A
B. Do the test given in Para.3.A.
[Rev.8 from Aug 2018] 2026.04.04 04:31:38 UTC