Disagree of the LO/DECEL Legend with the AUTO BRK/LO Pushbutton Switch not Selected ON
TASK 32-42-00-810-915-A
Disagree of the LO/DECEL Legend with the AUTO BRK/LO Pushbutton Switch not Selected ON
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 32-42-00-700-080-A
Subtask 32-42-00-810-172-A
[Rev.8 from Aug 2018]
2026.04.04 04:31:36 UTC
Disagree of the LO/DECEL Legend with the AUTO BRK/LO Pushbutton Switch not Selected ON
1. Possible Causes
- BOARD-ANN LT TEST & INTFC [1LP]
AUTO BRK/LO pushbutton switch - wiring
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ESPM 2045110 | |
| AMM 33-14-33-000-001 | Removal of the Annunciator-Light Test and Interface-Board |
| AMM 33-14-33-400-001 | Installation of the Annunciator-Light Test and Interface-Board |
Subtask 32-42-00-700-080-A
A. Test
Not applicable.
4. Fault IsolationNot applicable.
Subtask 32-42-00-810-172-A
A. If the DECEL legend of the AUTO BRK/LO pushbutton switch (8GG) gives an incorrect indication:
- replace the BOARD-ANN LT TEST & INTFC [1LP] AMM 33-14-33-000-001 and AMM 33-14-33-400-001.
- replace the
AUTO BRK/LO pushbutton switch (8GG) ESPM 2045110.
- do a check and repair the wiring from the ANN LT Test & INTFC board (1LP) pin A/10 to the AUTO BRK/LO pushbutton switch (8GG) pin A/7.