Loss of the Signal from the Green Pressure Switch
TASK 32-42-00-810-823-A
Loss of the Signal from the Green Pressure Switch
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 32-42-00-740-068-A
Subtask 32-42-00-810-072-B
[Rev.8 from Aug 2018]
2026.04.04 04:31:32 UTC
Loss of the Signal from the Green Pressure Switch
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 29-32-12-000-001 | Removal of the System Pressure Switch |
| AMM 29-32-12-400-001 | Installation of the System Pressure Switch |
| ASM 324203 | |
| AMM 32-42-34-000-001 | Removal of the Braking/Steering Control Unit (BSCU) |
| AMM 32-42-34-400-001 | Installation of the Braking/Steering Control Unit (BSCU) |
Subtask 32-42-00-740-068-A
A. Test
Not applicable
4. Fault IsolationNot applicable
Subtask 32-42-00-810-072-B
A. If the PFR gives the maintenance message GREEN SYSTEM PRESS SWITCH (1151GN):
Subtask 32-42-00-740-069-A - replace the SYSTEM-PRESS-SW [1151GN] AMM 29-32-12-000-001 and AMM 29-32-12-400-001.
- replace the BSCU [10GG] AMM 32-42-34-000-001 and AMM 32-42-34-400-001.
- do a check and repair the
wiring from the pressure switch (1151GN) to the BSCU (10GG) pin A/C to pin AA/13F ASM 324203.
B. After the subsequent flight, make sure that the fault does not continue.