W DOC AIRBUS | TSM A320F

Brightness too Low on the Upper ECAM DU


TASK 31-63-82-810-861-A
Brightness too Low on the Upper ECAM DU


1. Possible Causes
  • DU-ECAM, UPPER [4WT1]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 31-60-00-740-010
Operational Check of Brightness Control Through MCDU
AMM 31-63-22-000-001
Removal of the Display Unit
AMM 31-63-22-400-001
Installation of the Display Unit
3. Fault Confirmation
Subtask 31-63-82-710-056-A ** ON A/C NOT FOR ALL
A. Test
   (1) Do the operational check of the brightness control through the MCDU AMM 31-60-00-740-010.
4. Fault Isolation
Subtask 31-63-82-810-152-A ** ON A/C NOT FOR ALL
A. If the DU E/WD(4WT1) message comes into view:
   (1) Replace DU-ECAM, UPPER [4WT1] AMM 31-63-22-000-001 and AMM 31-63-22-400-001.
   (2) Do the test(s) given in the Para. Fault Confirmation.
Subtask 31-63-82-810-153-A ** ON A/C NOT FOR ALL
B. If the DU E/WD(4WT1) / BRIGHTNESS message comes into view and if the flight crew confirmed that the brightness was too low:
   (1) Replace DU-ECAM, UPPER [4WT1] AMM 31-63-22-000-001 and AMM 31-63-22-400-001.
   (2) Do the test(s) given in the Para. Fault Confirmation.
[Rev.8 from Aug 2018] 2026.04.04 04:31:18 UTC