W DOC AIRBUS | TSM A320F

Many Unwanted ECAM Alerts


TASK 31-63-82-810-853-A
Many Unwanted ECAM Alerts


1. Possible Causes
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 31-63-34-000-001
Removal of the DMC
AMM 31-63-34-400-001
Installation of the DMC
3. Fault Confirmation
Subtask 31-63-82-710-050-A ** ON A/C NOT FOR ALL
A. Not Applicable
4. Fault Isolation
Subtask 31-63-82-810-138-A ** ON A/C NOT FOR ALL
A. If an unwanted (spurious) warning/indication is shown on the ECAM diplay units:
   (1) On the SWITCHING panel 8VU, set the EIS DMC selector switch to CAPT/3.
     (a) If the warning/indication goes out of view:
       1 On the overhead C/B panel 49VU, open the circuit breaker 10WT1 for 5 seconds then close it.
     (b) If the warning/indication stays in view:
  • On the SWITCHING panel 8VU, set the EIS DMC selector switch to F/O/3.
       1 If the warning/indication goes out of view:
  • On the rear C/B panel 121VU, open the circuit breaker 10WT2 for 5 seconds then close it.
       2 If the warning/indication stays in view:
         a On the overhead C/B panel 121VU, open the circuit breaker 10WT3 for 5 seconds then close it.
         b On the rear C/B panel 49VU, open the circuit breaker 21WT3 for 5 seconds then close it.
Subtask 31-63-82-810-143-A ** ON A/C NOT FOR ALL
B. If the fault continues:
   (1) After the subsequent flight, if the fault continues on the same DMC:
[Rev.8 from Aug 2018] 2026.04.04 04:31:17 UTC