1. Possible Causes

2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 31-60-00-610-003
X LOADING Procedure of the DMC1
AMM 31-60-00-610-004
X LOADING Procedure of the DMC2
AMM 31-60-00-610-005
X LOADING Procedure of the DMC3
AMM 31-60-00-740-011
LRU Identification Check
AMM 31-60-00-860-001
EIS Start Procedure
AMM 31-60-00-860-002
EIS Stop Procedure
AWM 316128
AWM 316129
AWM 316130
3. Fault Confirmation
Subtask 31-63-82-860-116-A ** ON A/C NOT FOR ALL
A. Job Set-up
   (1) Do the EIS start procedure AMM 31-60-00-860-001.
4. Fault Isolation
Subtask 31-63-82-810-125-A ** ON A/C NOT FOR ALL
A. If the DMC VERSION INCONSISTENCY indication is shown on all the DU's:
   (1) Make sure that the software P/N of each DMC is the same that the P/N of the set of floppy disks
     (a) If the software P/N is different:
     (b) If the software P/N is the same:
5. Close-up
Subtask 31-63-82-860-117-A ** ON A/C NOT FOR ALL