Blank Screen on the Upper ECAM DU
TASK 31-63-82-810-837-A
Blank Screen on the Upper ECAM DU
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 31-63-82-860-094-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 31-63-82-810-112-A ** ON A/C NOT FOR ALL
Subtask 31-63-82-860-108-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:31:16 UTC
Blank Screen on the Upper ECAM DU
1. Possible Causes
- DU-ECAM, UPPER [4WT1]
- wiring
- C/B-EIS/ECAM DU/UPPER/SPLY [13WT1]
- C/B-EIS/ECAM DU/UPPER/SWTG [24WT1]
- CTL PNL-ECAM [6WT]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 31-60-00-860-001 | EIS Start Procedure |
| AMM 31-60-00-860-002 | EIS Stop Procedure |
| ASM 316102 | |
| AMM 31-63-22-000-001 | Removal of the Display Unit |
| AMM 31-63-22-400-001 | Installation of the Display Unit |
| ASM 316801 | |
| ASM 316803 |
Subtask 31-63-82-860-094-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 31-63-82-810-112-A ** ON A/C NOT FOR ALL
A. If the operational image is shown on the upper ECAM DU:
Subtask 31-63-82-810-113-A ** ON A/C NOT FOR ALL - no maintenance action is necessary.
B. If a maintenance message is shown on a black screen
Subtask 31-63-82-810-114-A ** ON A/C NOT FOR ALL - do the fault isolation procedure relative to this message.
C. If a blank screen (screen completely black) is shown on the upper ECAM DU:
(a) Do a check for 115VAC at pin AA-79 of the upper ECAM DU ASM 316102.
1 If there is no 115VAC:
5. Close-up- replace the DU-ECAM, UPPER [4WT1] AMM 31-63-22-000-001 and AMM 31-63-22-400-001.
(a) Do a check for 115VAC at pin AA-79 of the upper ECAM DU ASM 316102.
1 If there is no 115VAC:
- check the wiring from the upper ECAM SPLY-C/B (13WT1) to the upper ECAM DU(4WT1) pin AA-79.
- repair the wiring.
- replace the C/B-EIS/ECAM DU/UPPER/SPLY [13WT1] .
- do a check for a ground signal at pin A-77 of the upper ECAM DU.
- check and repair the wiring from the upper ECAM-DU pin AA-77 to the the ground terminal.
- do a check for 28VDC at the upper ECAM-DU pin AA-81
. if there is no 28VDC, check and repair the wiring from the upper ECAM-DU pin AA-81 to the upper ECAM DU -SWTG C/B (24WT1)
. if there is 28VDC, replace the C/B-EIS/ECAM DU/UPPER/SWTG [24WT1] .
- do a check for a ground signal at pin AA-75 of the upper ECAM DU ASM 316803.
- make sure there is no ground signal at pin B-D of the upper ECAM DU potentiometer (6WT1).
- check and repair the wiring from the upper ECAM DU potentiometer (6WT1) pin B-D to the upper ECAM DU (4WT1) pin AA-75.
- replace the CTL PNL-ECAM [6WT] .
- do a check and repair the wiring ASM 316801.
from the upper ECAM DU(4WT1) pin AA-39 to the ECAM CTL-PNL (6WT) pin B-B
from the upper ECAM DU(4WT1) pin AA-40 to the ECAM CTL-PNL (6WT) pin B-C
from the upper ECAM DU(4WT1) pin AA-36 to the ECAM CTL-PNL (6WT) pin B-U.
Subtask 31-63-82-860-108-A ** ON A/C NOT FOR ALL