W DOC AIRBUS | TSM A320F

Blank Screen on the FO PFD DU


TASK 31-63-82-810-835-A
Blank Screen on the FO PFD DU


1. Possible Causes
  • PFD-F/O [2WT2]
  • wiring
  • C/B-EIS/PFD/F/O [11WT2]
  • C/B-EIS/PFD/F/O/SWTG [22WT2]
  • POT-PFD, F/O [7WT2]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 31-60-00-860-001
EIS Start Procedure
AMM 31-60-00-860-002
EIS Stop Procedure
ASM 316102
AMM 31-63-22-000-001
Removal of the Display Unit
AMM 31-63-22-400-001
Installation of the Display Unit
ASM 316802
3. Fault Confirmation
Subtask 31-63-82-860-092-A ** ON A/C NOT FOR ALL
A. Job Set-up
   (1) Do the EIS start procedure AMM 31-60-00-860-001.
4. Fault Isolation
Subtask 31-63-82-810-106-A ** ON A/C NOT FOR ALL
A. If the operational image is shown on the FO PFD DU:
  • no maintenance action is necessary.
Subtask 31-63-82-810-107-A ** ON A/C NOT FOR ALL
B. If a maintenance message is shown on a black screen
  • do the fault isolation procedure relative to this message.
Subtask 31-63-82-810-108-A ** ON A/C NOT FOR ALL
C. If a blank screen (screen completely black) is shown on the FO PFD DU:
   (1) If the fault continues:
     (a) Do a check for 115VAC at pin AA-79 of the FO PFD DU ASM 316102.
       1 If there is no 115VAC:
  • check the wiring from the PFD FO SPLY-C/B (11WT2) to the FO PFD-DU(2WT2) pin AA-79.
         a If there is no continuity:
  • repair the wiring.
         b If there is continuity:
  • replace the C/B-EIS/PFD/F/O [11WT2] .
       2 If there is 115VAC:
  • do a check for a ground signal at pin A-77 of the FO PFD DU.
         a If there is no ground signal:
  • check and repair the wiring from the FO PFD-DU pin AA-77 to the the ground terminal.
         b If there is a ground signal:
  • do a check for 28VDC at the FO PFD-DU pin AA-81
    . if there is no 28VDC, check and repair the wiring from the FO PFD-DU pin AA-81 to the FO PFD-SWTG C/B (22WT2).
    . if there is 28VDC, replace the C/B-EIS/PFD/F/O/SWTG [22WT2] .
   (2) If the fault continues:
  • do a check for a ground signal at pin AA-75 of the FO PFD DU ASM 316802.
     (a) If there is a ground signal:
  • make sure there is no ground signal at pin 8 of the FO PFD potentiometer (7WT2).
       1 If there is no ground signal:
  • check and repair the wiring from the FO PFD-POT (7WT2) pin 8 to the FO PFD-DU (2WT2) pin AA-75.
       2 If there is a ground signal:
  • replace the POT-PFD, F/O [7WT2] .
5. Close-up
Subtask 31-63-82-860-106-A ** ON A/C NOT FOR ALL
A. CLose-up
[Rev.8 from Aug 2018] 2026.04.04 04:31:16 UTC