TASK 31-63-82-810-833-A
Blank Screen on the CAPT PFD DU
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 31-63-82-860-090-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 31-63-82-810-100-A ** ON A/C NOT FOR ALL
Subtask 31-63-82-860-104-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:31:16 UTC
Blank Screen on the CAPT PFD DU
1. Possible Causes
- PFD-CAPT [2WT1]
- wiring
- C/B-EIS/PFD/CAPT/SPLY [11WT1]
- C/B-EIS/PFD CAPT/SWTG [22WT1]
- POT-PFD, CAPT [7WT1]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 31-60-00-860-001 | EIS Start Procedure |
| AMM 31-60-00-860-002 | EIS Stop Procedure |
| ASM 316102 | |
| AMM 31-63-22-000-001 | Removal of the Display Unit |
| AMM 31-63-22-400-001 | Installation of the Display Unit |
| ASM 316801 | |
| ASM 316802 |
Subtask 31-63-82-860-090-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 31-63-82-810-100-A ** ON A/C NOT FOR ALL
A. If the operational image is shown on the CAPT PFD :
Subtask 31-63-82-810-101-A ** ON A/C NOT FOR ALL - no maintenance action is necessary.
B. If a maintenance message is shown on a black screen
Subtask 31-63-82-810-102-A ** ON A/C NOT FOR ALL - do the fault isolation procedure relative to this message.
C. If a blank screen (screen completely black) is shown on the CAPT PFD DU:
(a) Do a check for 115VAC at pin AA-79 of the CAPT PFD DU ASM 316102.
1 If there is no 115VAC:
5. Close-up- replace the PFD-CAPT [2WT1] AMM 31-63-22-000-001 and AMM 31-63-22-400-001.
(a) Do a check for 115VAC at pin AA-79 of the CAPT PFD DU ASM 316102.
1 If there is no 115VAC:
- check the wiring from the PFD CAPT SPLY-C/B (11WT1) to the CAPT PFD DU(2WT1) pin AA-79.
- repair the wiring.
- replace the C/B-EIS/PFD/CAPT/SPLY [11WT1] .
- do a check for a ground signal at pin A-77 of the CAPT PFD DU.
- check and repair the wiring from the CAPT PFD DU pin AA-77 to the the ground terminal.
- do a check for 28VDC at the pin AA-81 of the CAPT PFD DU
. if there is no 28VDC, check and repair the wiring from the CAPT PFD-DU pin AA-81 to the CAPT PFD-SWTG C/B (22WT1)
. if there is 28VDC, replace the C/B-EIS/PFD CAPT/SWTG [22WT1] .
- do a check for a ground signal at pin AA-75 of the CAPT PFD DU ASM 316802.
- make sure there is no ground signal at pin 8 of the CAPT PFD potentiometer (7WT1).
- check and repair the wiring from the CAPT PFD-POT (7WT1) pin 8 to the CAPT PFD- DU (2WT1) pin AA-75.
- replace the POT-PFD, CAPT [7WT1] .
- do a check and repair the wiring ASM 316801:
from the CAPT PFD-DU(2WT1) pin AA-39 to the CAPT PFD-POT(7WT1) pin A2
from the CAPT PFD-DU(2WT1) pin AA-40 to the CAPT PFD-POT(7WT1) pin A1
from the CAPT PFD-DU(2WT1) pin AA-36 to the CAPT PFD-POT(7WT1) pin A3.
Subtask 31-63-82-860-104-A ** ON A/C NOT FOR ALL