W DOC AIRBUS | TSM A320F

Loss of the Crossload Bus from the DMC1 to the DMC2


TASK 31-63-82-810-831-A
Loss of the Crossload Bus from the DMC1 to the DMC2


1. Possible Causes
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 31-60-00-740-007
GROUND SCANNING Test of the DMC
ASM 316100
AMM 31-63-34-000-001
Removal of the DMC
AMM 31-63-34-400-001
Installation of the DMC
3. Fault Confirmation
Subtask 31-63-82-740-072-A ** ON A/C NOT FOR ALL
A. Test
4. Fault Isolation
Subtask 31-63-82-810-099-A ** ON A/C NOT FOR ALL
A. If the GROUND SCANNING test gives the maintenance message DMC1(1WT1)/DMC2 (1WT2):
   (1) If the fault continues:
     (a) If the fault continues:
  • check and repair the wiring from the pins AB/11J and AB/11K of the DMC1 to the pins AE/12B and AE/12C of the DMC2 ASM 316100
Subtask 31-63-82-740-073-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:31:15 UTC