Transfer of the ECAM DU Image on the F/O ND not Possible
TASK 31-63-82-810-812-A
Transfer of the ECAM DU Image on the F/O ND not Possible
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 31-63-82-860-072-A
Subtask 31-63-82-810-070-A ** ON A/C NOT FOR ALL
Subtask 31-63-82-860-073-A
[Rev.8 from Aug 2018]
2026.04.04 04:31:15 UTC
Transfer of the ECAM DU Image on the F/O ND not Possible
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 31-60-00-860-001 | EIS Start Procedure |
| AMM 31-60-00-860-002 | EIS Stop Procedure |
| AMM 31-63-34-000-001 | Removal of the DMC |
| AMM 31-63-34-400-001 | Installation of the DMC |
| ASM 316801 | |
| ASM 316803 |
Subtask 31-63-82-860-072-A
A. Job Set-up
(1) Do the EIS start procedure AMM 31-60-00-860-001.
(2) When the images come into view on the six display units:
Subtask 31-63-82-700-072-A (1) Do the EIS start procedure AMM 31-60-00-860-001.
(2) When the images come into view on the six display units:
- set the ECAM/ND XFR selector switch (19WT) on the panel 8VU to F/O.
B. Test
Make sure that the transfer is not possible.
4. Fault IsolationMake sure that the transfer is not possible.
Subtask 31-63-82-810-070-A ** ON A/C NOT FOR ALL
A. If the EIS DMC selector switch (18WT) is at NORM and if you cannot get the ECAM DU image on the F/O ND:
Subtask 31-63-82-810-071-A ** ON A/C NOT FOR ALL - replace the SEL SW-ECAM/ND XFR [19WT] .
- do a check for a ground signal at pins AB/4B, 8J of the DMC2(1WT2).
- do a check for a ground signal at pin 5 of the ECAM/ND XFR selector switch (19WT).
- repair the wiring from ECAM/ND XFR selector switch (19WT) pin 5 to the ground terminal ASM 316803.
- do a check and repair the wiring from ECAM/ND XFR selector switch (19WT) pin 6 to DMC2 (1WT2) pin AB/4B, 8J.
- replace the DMC-2 [1WT2] AMM 31-63-34-000-001 and AMM 31-63-34-400-001 ASM 316803.
B. If the EIS DMC selector switch (18WT) is at F/O/3 and if you cannot get the ECAM DU image on the F/O ND:
Subtask 31-63-82-810-070-B ** ON A/C NOT FOR ALL - replace the SEL SW-ECAM/ND XFR [19WT] .
- do a check for a ground signal at pin AB/4B of the DMC3 (1WT3)
- do a check for a ground signal at pin 5 of the ECAM/ND XFR selector switch (19WT).
- repair the wiring from ECAM/ND XFR selector switch (19WT) pin 5 to the ground terminal ASM 316803.
- do a check and repair the wiring from ECAM/ND XFR selector switch (19WT) pin 6 to DMC3 (1WT3) pin AB/4B.
- do a check for a ground signal at pin AB/8J of the DMC3 (1WT3).
- do a check for a ground signal at pin 13 of the EIS DMC selector switch (18WT).
- repair the wiring from EIS DMC selector switch (18WT) pin 13 to the ground terminal.
- do a check and repair the wiring from ECAM/ND XFR selector switch (19WT):
. pin 14 to EIS DMC selector switch (18WT) pin 14
. pin 13 to DMC3 (1WT3) pin AB/8J.
- replace the DMC-3 [1WT3] AMM 31-63-34-000-001 and AMM 31-63-34-400-001.
C. If the EIS-DMC selector switch (18WT) is at NORM and you cannot get the ECAM DU image on the F/O ND DU:
Subtask 31-63-82-810-071-B ** ON A/C NOT FOR ALL - do a check for a ground signal at the pin AE-4D of the DMC2 (1WT2)
- replace the DMC-2 [1WT2] AMM 31-63-34-000-001 and AMM 31-63-34-400-001.
- do a check and repair the wiring from the pin AE-4D of the DMC2 (1WT2) to the first terminal block ASM 316801
D. If the EIS-DMC selector switch (18WT) is at F/O/3 and you cannot get the ECAM DU image on the F/O ND DU:
Subtask 31-63-82-810-131-A ** ON A/C NOT FOR ALL - do a check for a ground signal at the pin AE-4D of the DMC3 (1WT3)
- replace the DMC-3 [1WT3] AMM 31-63-34-000-001 and AMM 31-63-34-400-001.
- do a check and repair the wiring from the pin AE-4D of the DMC3 (1WT3) to the first terminal block ASM 316803
E. If you cannot get the image at the F/O ND DU when the EIS DMC selector switch (18WT) is at NORM or at F/O/3 position:
Subtask 31-63-82-700-073-A - do a check for a ground signal at the pin 5 of the ECAM/ND XFR selector switch (19WT)
- do a check and repair the wiring from the pin 5 of the ECAM/ND XFR selector switch (19WT) to the first terminal block ASM 316803
- do a check and repair the wiring from the pin 8 of the ECAM/ND XFR selector switch (19WT) to the first terminal block ASM 316801
- replace the SEL SW-ECAM/ND XFR [19WT] .
F. Set the ECAM/ND XFR selector switch (19WT) to F/O and make sure that the transfer is possible.
5. Close-upSubtask 31-63-82-860-073-A