1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 31-63-82-860-070-A
Subtask 31-63-82-810-068-A ** ON A/C NOT FOR ALL
Subtask 31-63-82-860-071-A
[Rev.8 from Aug 2018]
2026.04.04 04:31:15 UTC
Transfer of the ECAM DU Image on the CAPT ND not Possible
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 31-60-00-860-001 | EIS Start Procedure |
| AMM 31-60-00-860-002 | EIS Stop Procedure |
| AMM 31-63-34-000-001 | Removal of the DMC |
| AMM 31-63-34-400-001 | Installation of the DMC |
| ASM 316801 | |
| ASM 316803 |
Subtask 31-63-82-860-070-A
A. Job Set-up
(1) Do the EIS start procedure AMM 31-60-00-860-001.
(2) When the images come into view on the six display units:
Subtask 31-63-82-700-070-A (1) Do the EIS start procedure AMM 31-60-00-860-001.
(2) When the images come into view on the six display units:
- set the ECAM/ND XFR selector switch (19WT) on the panel 8VU to CAPT.
B. Test
Make sure that the transfer is not possible.
4. Fault IsolationMake sure that the transfer is not possible.
Subtask 31-63-82-810-068-A ** ON A/C NOT FOR ALL
A. If the EIS DMC selector switch (18WT) is at NORM and if you cannot get the ECAM DU image on the CAPT ND:
Subtask 31-63-82-810-069-A ** ON A/C NOT FOR ALL - replace the SEL SW-ECAM/ND XFR [19WT] .
- do a check for a ground signal at pins AB/4B, 8J of the DMC1 (1WT1).
- do a check for a ground signal at pin 5 of the ECAM/ND XFR selector switch (19WT).
- repair the wiring from ECAM/ND XFR selector switch (19WT) pin 5 to the ground terminal ASM 316803.
- do a check and repair the wiring from ECAM/ND XFR selector switch (19WT) pin 6 to DMC1 (1WT1) pin AB/4B, 8J.
- replace the DMC-1 [1WT1] AMM 31-63-34-000-001 and AMM 31-63-34-400-001 ASM 316803.
B. If the EIS DMC selector switch (18WT) is at CAPT/3 and if you cannot get the ECAM DU image on the CAPT ND:
Subtask 31-63-82-810-068-B ** ON A/C NOT FOR ALL - replace the SEL SW-ECAM/ND XFR [19WT] .
- do a check for a ground signal at pin AB/4B of the DMC3 (1WT3).
- do a check for a ground signal at pin 5 of the ECAM/ND XFR selector switch (19WT).
- repair the wiring from ECAM/ND XFR selector switch (19WT) pin 5 to the ground terminal ASM 316803.
- do a check and repair the wiring from ECAM/ND XFR selector switch (19WT) pin 6 to DMC3 (1WT3) pin AB/4B.
- do a check for a ground signal at pin AB/8J of the DMC3 (1WT3).
- do a check for a ground signal at pin 13 of the EIS DMC selector switch (18WT).
- repair the wiring from EIS DMC selector switch (18WT) pin 13 to the ground terminal.
- do a check and repair the wiring from ECAM/ND XFR selector switch (19WT):
. pin 16 to EIS DMC selector switch (18WT) pin 16
. pin 13 to DMC3 (1WT3) pin AB/8J.
- replace the DMC-3 [1WT3] AMM 31-63-34-000-001 and AMM 31-63-34-400-001.
C. If the EIS-DMC selector switch (18WT) is at NORM and you cannot get the image on the CAPT ND DU:
Subtask 31-63-82-810-069-B ** ON A/C NOT FOR ALL - do a check for a ground signal at the pin AE-4D of the DMC1 (1WT1)
- replace the DMC-1 [1WT1] AMM 31-63-34-000-001 and AMM 31-63-34-400-001.
- do a check and repair the wiring from the pin AE-4G of the DMC1 (1WT1) to the first terminal block ASM 316801
D. If the EIS-DMC selector switch (18WT) is at CAPT/3 and you cannot get the image on the CAPT ND DU:
Subtask 31-63-82-810-130-A ** ON A/C NOT FOR ALL - do a check for a ground signal at the pin AE-4D of the DMC3 (1WT3)
- replace the DMC-3 [1WT3] AMM 31-63-34-000-001 and AMM 31-63-34-400-001.
- do a check and repair the wiring from the pin AE-4G of the DMC3 (1WT3) to the first terminal block ASM 316803
E. If you cannot get the image at the CAPT ND DU when the EIS DMC selector switch (18WT) is at NORM or at CAPT/3 position:
Subtask 31-63-82-700-071-A - do a check for a ground signal at the pin 5 of the ECAM/ND XFR selector switch (19WT)
- do a check and repair the wiring from the pin 5 of the ECAM/ND XFR selector switch (19WT) to the first terminal block ASM 316803
- do a check and repair the wiring from the pin 6 of the ECAM/ND XFR selector switch (19WT) to the first terminal block ASM 316801
- replace the SEL SW-ECAM/ND XFR [19WT] .
F. Set the ECAM/ND XFR selector switch (19WT) to CAPT and make sure that the transfer is possible.
5. Close-upSubtask 31-63-82-860-071-A