W DOC AIRBUS | TSM A320F

Loss of the CAPT PFD, CAPT ND and Upper ECAM DU


TASK 31-63-82-810-801-A
Loss of the CAPT PFD, CAPT ND and Upper ECAM DU


1. Possible Causes
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 31-60-00-860-001
EIS Start Procedure
AMM 31-60-00-860-002
EIS Stop Procedure
ASM 316102
AMM 31-63-34-000-001
Removal of the DMC
AMM 31-63-34-400-001
Installation of the DMC
3. Fault Confirmation
Subtask 31-63-82-860-050-A ** ON A/C NOT FOR ALL
A. Job Set-up
Do the EIS start procedure (CAPT PFD, CAPT ND and upper ECAM DU only) AMM 31-60-00-860-001.
Subtask 31-63-82-700-050-A ** ON A/C NOT FOR ALL
B. Test
Make sure that the display units display a diagonal line.
4. Fault Isolation
Subtask 31-63-82-810-050-A ** ON A/C NOT FOR ALL
A. If the three display units display a diagonal line and if the EIS DMC selector switch (18WT) on the SWITCHING panel 8VU is at NORM:
   (1) Do a check for 115VAC at pin AC/2 of the DMC1 (1WT1) ASM 316102.
     (a) If there is 115VAC:
     (b) If there is no 115VAC:
  • do a check for a ground signal at pin AC/7 of the DMC1 (1WT1).
       1 If there is no ground signal:
  • repair the wiring from DMC1 (1WT1) pin AC/7 to the ground terminal.
       2 If there is a ground signal:
  • do a check of the wiring from DMC1 (1WT1) pin AC/2 to the circuit breaker (10WT1).
         a If there is no continuity:
  • repair the wiring.
         b If there is continuity:
  • replace the C/B-EIS/DMC1/SPLY [10WT1] .
Subtask 31-63-82-810-051-A ** ON A/C NOT FOR ALL
B. If the three display units display a diagonal line and if the EIS DMC selector switch (18WT) on the SWITCHING panel 8VU is at CAPT/3:
   (1) Do a check for 28VDC at pin AC/3 of the DMC3 (1WT3) ASM 316102.
     (a) If there is 28VDC:
     (b) If there is no 28VDC:
  • do a check for a ground signal at pin AC/11 of the DMC3 (1WT3)
       1 If there is no ground signal:
  • repair the wiring from DMC3 (1WT3) pin AC/11 to the ground terminal.
       2 If there is a ground signal:
  • do a check of the wiring from DMC3 (1WT3) pin AC/3 to the circuit breaker (21WT3).
         a If there is no continuity:
  • repair the wiring.
         b If there is continuity:
  • replace the C/B-EIS/DMC3/SWTG [21WT3] .
Subtask 31-63-82-700-051-A ** ON A/C NOT FOR ALL
C. Do the EIS start procedure (CAPT PFD, CAPT ND and upper ECAM DU only) AMM 31-60-00-860-001 and make sure that the display units come on.
5. Close-up
Subtask 31-63-82-860-051-A ** ON A/C NOT FOR ALL
A. Do the EIS stop procedure AMM 31-60-00-860-002.
[Rev.8 from Aug 2018] 2026.04.04 04:31:13 UTC