W DOC AIRBUS | TSM A320F

Failure of the A629 BUS from the Lower ECAM DU to the DMC2


TASK 31-63-81-810-971-A
Failure of the A629 BUS from the Lower ECAM DU to the DMC2


1. Possible Causes
  • wiring
  • DU-ECAM, LOWER [4WT2]
  • DMC-2 [1WT2]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 31-60-00-720-002
Operational Test of the DMC/DU data bus
ASM 316104
AMM 31-63-22-000-001
Removal of the Display Unit
AMM 31-63-22-400-001
Installation of the Display Unit
AMM 31-63-34-000-001
Removal of the DMC
AMM 31-63-34-400-001
Installation of the DMC
3. Fault Confirmation
Subtask 31-63-81-720-097-A ** ON A/C NOT FOR ALL
A. Test
Do the operational test of the DMC/DU Data Bus AMM 31-60-00-720-002.
4. Fault Isolation
Subtask 31-63-81-810-256-A ** ON A/C NOT FOR ALL
A. If the test gives:
   (1) The maintenance message DU SD(4WT2)/DMC2(1WT2):
  • Check the wiring between the Lower ECAM DU (4WT2) and the DMC2 ASM 316104.
     (a) If the wiring is correct:
     (b) If the fault continues:
Subtask 31-63-81-720-098-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:40:11 UTC