Failure of the A629 BUS from the Upper ECAM DU to the DMC1
TASK 31-63-81-810-964-A
Failure of the A629 BUS from the Upper ECAM DU to the DMC1
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 31-63-81-720-083-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 31-63-81-810-249-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:31:09 UTC
Failure of the A629 BUS from the Upper ECAM DU to the DMC1
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 31-60-00-720-002 | Operational Test of the DMC/DU data bus |
| ASM 316104 | |
| AMM 31-63-22-000-001 | Removal of the Display Unit |
| AMM 31-63-22-400-001 | Installation of the Display Unit |
| AMM 31-63-34-000-001 | Removal of the DMC |
| AMM 31-63-34-400-001 | Installation of the DMC |
Subtask 31-63-81-720-083-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 31-63-81-810-249-A ** ON A/C NOT FOR ALL
A. If the test gives:
(1) The maintenance message DU EWD(4WT1)/DMC1(1WT1):
Subtask 31-63-81-720-084-A ** ON A/C NOT FOR ALL (1) The maintenance message DU EWD(4WT1)/DMC1(1WT1):
- Check the wiring between the Upper ECAM DU (4WT1) and the DMC1 ASM 316104.
- Replace the DU-ECAM, UPPER [4WT1] AMM 31-63-22-000-001 and AMM 31-63-22-400-001.
- Replace the DMC-1 [1WT1] AMM 31-63-34-000-001 and AMM 31-63-34-400-001.
B. Do the test given in Para. 3.