Failure of the A629 BUS from the ND CAPT DU to the DMC1
TASK 31-63-81-810-961-A
Failure of the A629 BUS from the ND CAPT DU to the DMC1
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 31-63-81-720-077-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 31-63-81-810-246-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:40:11 UTC
Failure of the A629 BUS from the ND CAPT DU to the DMC1
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 31-60-00-720-002 | Operational Test of the DMC/DU data bus |
| ASM 316104 | |
| AMM 31-63-22-000-001 | Removal of the Display Unit |
| AMM 31-63-22-400-001 | Installation of the Display Unit |
| AMM 31-63-34-000-001 | Removal of the DMC |
| AMM 31-63-34-400-001 | Installation of the DMC |
Subtask 31-63-81-720-077-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 31-63-81-810-246-A ** ON A/C NOT FOR ALL
A. If the test gives:
(1) The maintenance message DU ND CAPT(3WT1)/DMC1(1WT1):
Subtask 31-63-81-720-078-A ** ON A/C NOT FOR ALL (1) The maintenance message DU ND CAPT(3WT1)/DMC1(1WT1):
- Check the wiring between the CAPT ND DU (3WT1) and the DMC1 ASM 316104.
- Replace the ND-CAPT [3WT1] AMM 31-63-22-000-001 and AMM 31-63-22-400-001.
- Replace the DMC-1 [1WT1] AMM 31-63-34-000-001 and AMM 31-63-34-400-001.
B. Do the test given in Para. 3.