Failure of the LRU Identification on the DMC2
TASK 31-63-81-810-943-A
Failure of the LRU Identification on the DMC2
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 31-63-81-860-083-A ** ON A/C NOT FOR ALL
Subtask 31-63-81-810-224-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:31:07 UTC
Failure of the LRU Identification on the DMC2
1. Possible Causes
- DMC-2 [1WT2]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 31-60-00-610-803 | Uploading of DMC1 Software with the Portable Data Loader (SFIM Manufacturer or equivalent) |
| AMM 31-60-00-740-004 | EIS System Test |
| AMM 31-60-00-740-011 | LRU Identification Check |
| AMM 31-63-34-000-001 | Removal of the DMC |
| AMM 31-63-34-400-001 | Installation of the DMC |
Subtask 31-63-81-860-083-A ** ON A/C NOT FOR ALL
A. Reset the DU
(1) On the overhead C/B panel (121VU):
Subtask 31-63-81-740-328-A ** ON A/C NOT FOR ALL 4. Fault Isolation(1) On the overhead C/B panel (121VU):
- open then close the circuit breaker 10WT2
- no maintenance action is necessary.
- do the following test.
Subtask 31-63-81-810-224-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message INVALID LRU IDENT:
(a) If the part numbers are the same:
Subtask 31-63-81-740-329-A ** ON A/C NOT FOR ALL - Do the LRU Identification Check AMM 31-60-00-740-011
(a) If the part numbers are the same:
- replace the DMC-2 [1WT2] AMM 31-63-34-000-001 AMM 31-63-34-400-001
- do the uploading of the DMC2 AMM 31-60-00-610-803
B. Do the test given in Para. 3.A